All Categories
History
Price (excluding tax)
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Cable hole
Classification
Cooling water amount (L/h)
Cooling water water pressure (MPa)
Defrosting method
Dimensions Depth (mm)
Dimensions Height (mm)
Dimensions Width (mm)
Door (width x height) (mm)
Electrical characteristics ELB capacity (A)
Electrical characteristics Maximum load current (A)
Electrical characteristics Power supply
Exterior/interior materials
Floor load capacity (kN/㎡)
Humidity range (RH)
Indoor light (capacity 60W) (pcs)
Internal dimensions Depth (mm)
Internal dimensions Height (mm)
Internal dimensions Width (mm)
Observation window (width x height) (mm)
Operation unit equipment
Operation unit exterior
Space temperature and humidity deviation (℃/RH)
Temperature and humidity fluctuation (℃/RH)
Temperature change rate
Temperature control (humidity control) unit (unit)
Temperature range (℃)
Temperature/humidity gradient (℃/RH)
Test room floor area (㎡)
Time to reach extreme temperature
Part Number
ER-105HHPProduct
Environmental test equipment (Cosmopia R) Constant temperature and humidity chamber standard seriesHandling Company
Kyushu Kiden Co., Ltd.Categories
Image | Price (excluding tax) | Cable hole | Classification | Cooling water amount (L/h) | Cooling water water pressure (MPa) | Defrosting method | Dimensions Depth (mm) | Dimensions Height (mm) | Dimensions Width (mm) | Door (width x height) (mm) | Electrical characteristics ELB capacity (A) | Electrical characteristics Maximum load current (A) | Electrical characteristics Power supply | Exterior/interior materials | Floor load capacity (kN/㎡) | Humidity range (RH) | Indoor light (capacity 60W) (pcs) | Internal dimensions Depth (mm) | Internal dimensions Height (mm) | Internal dimensions Width (mm) | Observation window (width x height) (mm) | Operation unit equipment | Operation unit exterior | Space temperature and humidity deviation (℃/RH) | Temperature and humidity fluctuation (℃/RH) | Temperature change rate | Temperature control (humidity control) unit (unit) | Temperature range (℃) | Temperature/humidity gradient (℃/RH) | Test room floor area (㎡) | Time to reach extreme temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Φ50×1 location (with rubber plug) | Water-cooled HHP type | 2,400 | 0.1~0.5 | Off-cycle defrosting (refrigerator operation stopped, room temperature 5~40℃) ・Temperature rise defrosting (room temperature -10~5℃) | 2,700 | 2,325 | 3,600 | 830×1,800 single opening/1 location | 100 | 65 | Three phase 200V 50/60Hz | Color steel plate (ivory)/stainless steel plate | 5.9 | 10~95% | 2 | 2,550 | 2,100 | 3,450 | 190×320 door section/1 location | Color lcd display panel | Painted steel plate (natural gray (Munsell symbol 1.0Y8.5/0.5)) | ±2.0/±5.0% | ±0.3/±2.5% | Rise: 1.5℃/min (-19~69℃) Descending: 0.8℃/min (69~-19℃) | EU-65HH×1 | -30~80 | ±2.5/±8.0% | 9.7 | Rising: within 70 minutes (20~80℃) Descending: within 110 minutes (20~-30℃) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
29.5hrs
Company Review
5.0