All Categories
History
Price (excluding tax)
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Acceleration/deceleration time
Braking torque DC braking
Braking torque Minimum connectable resistance value (Ω)
Braking torque Regenerative braking short time
Control method
Display monitor
EMC filter
Frequency accuracy
Frequency resolution
Input signal Forward/reverse run/stop External port
Input signal Forward/reverse run/stop External signal
Input signal Forward/reverse run/stop Operator
Input signal Frequency setting External port
Input signal Frequency setting External signal
Input signal Frequency setting Operator
Input signal Thermistor input terminal
Output frequency range
Output signal Intelligent monitor output terminal
Output signal Intelligent output terminal
Overload current rating
Protection function
Protective structure
Rated capacity (kVA) 400V
Rated capacity (kVA) 480V
Rated input AC voltage
Rated output current (A)
Rated output voltage
Usage environment Ambient temperature/storage temperature/humidity
Voltage/frequency characteristics
Zero phase reactor
Part Number
SJH700-16HFFHandling Company
Kyushu Kiden Co., Ltd.Categories
Image | Price (excluding tax) | Acceleration/deceleration time | Braking torque DC braking | Braking torque Minimum connectable resistance value (Ω) | Braking torque Regenerative braking short time | Control method | Display monitor | EMC filter | Frequency accuracy | Frequency resolution | Input signal Forward/reverse run/stop External port | Input signal Forward/reverse run/stop External signal | Input signal Forward/reverse run/stop Operator | Input signal Frequency setting External port | Input signal Frequency setting External signal | Input signal Frequency setting Operator | Input signal Thermistor input terminal | Output frequency range | Output signal Intelligent monitor output terminal | Output signal Intelligent output terminal | Overload current rating | Protection function | Protective structure | Rated capacity (kVA) 400V | Rated capacity (kVA) 480V | Rated input AC voltage | Rated output current (A) | Rated output voltage | Usage environment Ambient temperature/storage temperature/humidity | Voltage/frequency characteristics | Zero phase reactor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible | Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) | 35 | Built-in BRD circuit (separate discharge resistor) | PWM method | Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. | Built-in (EN61800-3 cat.C3) | Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency | Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) | Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) | Forward run/stop (1a, 1b selectable, 3 wire input possible) | Run/stop (switch forward/reverse with code) | Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) | DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) | Setting by UP key/DOWN key | 1 terminal (PTC characteristics/NTC characteristics) | 0.1~2,000Hz | Analog voltage output, analog current output, pulse output | Open collector 5 terminals, relay output (1C contact) 1 terminal selection (Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.) | 150%/60 seconds, 200%/3 seconds | Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, Phase loss error, braking resistor overload, CT error, external trip, communication error, option error | IP20 | 17.3 | 20.7 | Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz | Twenty five | Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) | -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) | V/f arbitrary setting, V/f control (constant torque, reduced torque) | Built-in |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
29.3hrs
Company Review
5.0