All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
24.0hours
Relatively Fast Response
■3 outputs, 10W, unit type AC/DC switching power supply ・10W, triple type with 3 outputs Lightweight, compact, and low price - Input and output terminals are European terminals. Easy to handle as no crimp terminals are required for wiring ・V1, V2, and V3 are isolated ・Wide input compatible (AC85-264V) ・Equipped with overcurrent protection, overvoltage protection, and short circuit protection circuits ・RoHS compliant ・Output voltage can be adjusted within a range of ±5% using the volume (Vadj) on the front panel (output adjustment is possible only on the V1 side) - Equipped with LED to easily determine power supply abnormalities (turns off in case of abnormality) ・Noise terminal voltage EN55022 class B compatible ・Acquired safety standards UL60950, EN60950, GB4943 ・CE mark obtained. Compliant with Electrical Appliance and Material Safety Act (PSE) - Compatible with harmonic current regulations [IEC61000-3-2 compliant] [EN61000-4-2 compliant] Electrostatic discharge [EN61000-4-3 compliant] Radioactive radio frequency electromagnetic field [EN61000-4-4 compliant] Fast transient burst [EN61000-4-5 compliant] Lightning surge common mode [EN61000-4-6 compliant] Conducted radio frequency electromagnetic field [EN61000-4-8 compliant] Power frequency magnetic field immunity [EN61000-4-11 compliant] Voltage dip/fluctuation
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Cooling method
Dimensions (mm)
EMC standard
Input fluctuation
Input leakage current
Input voltage (V)
Inrush current
Number of outputs
Operating temperature
Output capacity
Output current variable range
Overcurrent protection
Overvoltage protection
Retention time
Rise time
Safety standards
Short circuit protection
Storage temperature
Warranty period
Withstand voltage
Part Number
AK10W-TLProduct
Standard power supply multi 3chHandling Company
Acon Co., Ltd.Categories
Image | Price (excluding tax) | Cooling method | Dimensions (mm) | EMC standard | Input fluctuation | Input leakage current | Input voltage (V) | Inrush current | Number of outputs | Operating temperature | Output capacity | Output current variable range | Overcurrent protection | Overvoltage protection | Retention time | Rise time | Safety standards | Short circuit protection | Storage temperature | Warranty period | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Natural air cooling | 100 (width) x 58 (vertical) x 31 (height) | EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 | ±0.5% or less (input AC85~264V at 100% load) | At 230V input: 0.50mA or less | AC85~264V | 115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) | 3 | -10 ~ +70℃ (humidity 20~93%) | 10W | ±5% | Yes (105~150%, hiccup mode, automatic recovery) | Yes (output cutoff, clamped with Zener diode) | 20ms typ. (at 100% load) | 50ms typ. (at 100% load) | UL60950, EN60950, GB4943 | Yes | -20 ~ +85℃ (humidity 20~95%) | 3 years | Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
24.0hrs