All Categories
History
Price (excluding tax)
Variable power supply (variable output voltage type) ■Applications Applications where you want to vary large amounts of power ■Features Variable power supply. Output voltage can be varied from 0 to 100% using remote input (0 to 5V). The 800W type has a 5V output, so it can be used with only a variable resistor. Ideal for motor testing, etc. ■Input voltage range (V) 400W type: AC85~132/170~264V (switchable) /800W type: AC115V only ■400W, unit type AC/DC programmable switching power supply ・400W, single output. High performance DC0~110V programmable power supply ・Output voltage can be varied in the range of 0.1 to 100% by remote input (0 to 5V) *There is no 5V output from inside this power supply, so it cannot be varied using only the variable resistor volume. *A 20cm long control cable is included as a standard service. ・Wide input compatible (input AC100V, 200V switch switching) - Equipped with LED to easily determine power supply abnormalities (turns off in case of abnormality) ・Terminal block screw (M4) ・Compliant with safety standards UL60950, EN60950, GB4943
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Cooling method
Dimensions (mm)
Input fluctuation
Input leakage current
Input voltage (V)
Inrush current
Number of outputs
Operating temperature
Output
Output capacity
Output voltage variable range
Overcurrent protection
Overvoltage protection
Retention time
Rise time
Short circuit protection
Storage temperature
Warranty period
Withstand voltage
EMC standard
Safety standards
Overheating protection
Part Number
AK400W-SVRHandling Company
Acon Co., Ltd.Categories
Image | Price (excluding tax) | Cooling method | Dimensions (mm) | EMC standard | Input fluctuation | Input leakage current | Input voltage (V) | Inrush current | Number of outputs | Operating temperature | Output capacity | Output voltage variable range | Overcurrent protection | Overvoltage protection | Retention time | Rise time | Safety standards | Short circuit protection | Storage temperature | Warranty period | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Forced air cooling | 215 (width) x 115 (vertical) x 50 (height) | Meet GB9254, EN55022 classA, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 | ±0.5% or less (at 100% load) | At 230V input: 0.7mA or less | AC85~132V/AC170~264V | 115V input: 30A or less / 230V input: 60A or less (at 25℃, cold start) | 1 | -20 ~ +50℃ (humidity 20~93%) | 400W | 0~100%/0~110V | Yes (105% or more, current limit, automatic recovery) | Yes (115~150%, shutdown, restart required) | 20ms typ. (at 100% load) | 100ms typ. (at 100% load) | Meet GB4943, UL60950, EN60950 | Yes (blocking, automatic recovery) | -20 ~ +85℃ (humidity 20~95%) | 3 years | Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
Reviews shown here are reviews of companies.