■600W, unit type AC/DC switching power supply ・600W, DC12V high voltage, compact power supply ・AC200V input (AC170-264V) Since it only uses AC200V input, it is perfect for those looking for a power supply with good cost performance. ・Equipped with overcurrent protection, overvoltage protection, short circuit protection, and overheating protection circuits ・Equipped with cooling fan ・The output voltage can be adjusted within a range of ±10% using the volume (Vadj) on the front panel. - Equipped with LED to easily determine power supply abnormalities (turns off in case of abnormality)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Capacity
Cooling method
Dimensions (mm)
EMC standard
Input fluctuation
Input frequency
Input leakage current
Input voltage
Input voltage (V)
Inrush current
Number of outputs
Operating temperature
Output voltage variable range
Output voltage/current
Overcurrent protection
Overvoltage protection
Retention time
Rise time
Safety standards
Short circuit protection
Storage temperature
Warranty period
Withstand voltage
Overheating protection
Part Number
AK600W-SEHandling Company
Acon Co., Ltd.Categories
Image | Price (excluding tax) | Capacity | Cooling method | Dimensions (mm) | EMC standard | Input fluctuation | Input frequency | Input leakage current | Input voltage | Input voltage (V) | Inrush current | Number of outputs | Operating temperature | Output voltage variable range | Overcurrent protection | Overheating protection | Overvoltage protection | Retention time | Rise time | Safety standards | Short circuit protection | Storage temperature | Warranty period | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 600W | Cooling fan | 241 (width) x 124 (vertical) x 65 (height) | Design refer to GB9254, EN55022 classA | ±0.5% or less (at 100% load) | 47~63Hz | At 220V input: 1mA or less | AC200V (170~264V) | AC170~264V | At 115V input: 30A or less (at 25℃, cold start) | 1 | -20 ~ +50℃ (humidity 20~93%) | ±10% | Yes (110~130%, current limit, automatic recovery) | Yes | Yes (115~150%, shutdown, restart required) | 20ms typ. (at 100% load) | 50ms typ. (at 100% load) | Design refer to GB4943,UL60950,EN60950 | Yes | -20 ~ +85℃ (humidity 20~95%) | 3 years | Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |