■Summary A current of 10A is passed through the contact part, and the resistance value is calculated using the four-terminal method.In the previous model, increasing and decreasing the current had to be done manually, but in addition to automating this process, the machine is equipped with a printer. , greatly improved measurement and measurement result recording work. ■Features - Breaker-friendly measurement The measured current is slowly increased from 0 to the rated value over a period of about 10 seconds, the resistance value is measured, and then it is decreased over the same period of time. All of these operations are performed automatically. 。 This function makes it possible to minimize the influence on the bushing current transformer attached to the circuit breaker. ・Measurement result display/print function Measurement results for three phases can be displayed and printed all at once. - Shape that is easy to use on site Outdoor and other sites require a shape that makes it easy to perform a series of tasks such as transportation, preparation, measurement, and cleanup. These are the features of our existing product (CVE-2), and this product also inherits those features. I am.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Accessories
Carrying current
External dimensions
Measurement accuracy
Measuring range Range 1
Measuring range Range 2
Measuring range Range 3
Measuring range Range 4
Power supply
Weight
Measurement method
Option
Part Number
CVE-18Product
Low resistance measuring deviceHandling Company
CB Engineering Co., Ltd.Categories
Image | Price (excluding tax) | Accessories | External dimensions | Measurement accuracy | Measurement method | Measuring range Range 1 | Measuring range Range 2 | Measuring range Range 3 | Measuring range Range 4 | Option | Power supply | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Current cable (10m) 1 set Voltage cable (10m) 1 set 1 power cord (2m) | 280mm×450mm×290mm | ±0.5% (percentage of full scale for each range) | Four terminal method | Carrying current 10A Measurement range 0.001~0.2mΩ | Carrying current 10A Measurement range 0.01~2mΩ | Carrying current 10A Measuring range 0.1~20mΩ | Carrying current 1A Measurement range 1~200mΩ | Standard resistor 100μΩ (500A 50mV ±0.2%) | AC100V ±10% 200VA (fuse 3A) | 13 kg (body only) |