All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Additional functions
Alarm function
CT input type
Communication function
Communication method
Communication speed
Control input
Control input accuracy
Control input resolution
Control method
Control output
Current detector input (CT)
Factory initial settings
Input impedance
Input type
Leakage current when output is OFF
Load power supply voltage measurement input (PT input)
Load power supply voltage measurement input Allowable frequency fluctuation
Load power supply voltage measurement input Number of input points
Load power supply voltage measurement input input range
Load power supply voltage measurement input sampling period
Maximum number of connected devices
Minimum ON time
Number of channels
Output Allowable load current
Output load voltage
Power supply voltage
Sampling period
Synchronization method
Voltage drop when output is ON
Part Number
IOPD16-L-C*L6NHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Additional functions | Alarm function | CT input type | Communication function | Communication method | Communication speed | Control input | Control input accuracy | Control input resolution | Control method | Control output | Current detector input (CT) | Factory initial settings | Input impedance | Input type | Leakage current when output is OFF | Load power supply voltage measurement input (PT input) | Load power supply voltage measurement input Allowable frequency fluctuation | Load power supply voltage measurement input Number of input points | Load power supply voltage measurement input input range | Load power supply voltage measurement input sampling period | Maximum number of connected devices | Minimum ON time | Number of channels | Output Allowable load current | Output load voltage | Power supply voltage | Sampling period | Synchronization method | Voltage drop when output is ON |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Peak power suppression function, slope setting function, output monitor function | Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm | 16 points CTL-36-S56-20 (through type), CTL-24-CLS (clamp type) [Current transformation ratio 2,000:1] | RS-485 [2-wire] MODBUS protocol | RS-485 2-wire half-duplex multidrop connection | 9,600bps, 19,200bps, 38,400bps, 57,600bps | Upper controller transistor (open collector) output (sink method) Input pulse L active | ±1% OF SPAN (accuracy of captured manipulated variable) | Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 Time proportional cycle setting 1~100 seconds: approx. 1/100~1/10,000 | Zero cross control (continuous proportion) | Transistor output (source method) | Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included | None (no initial setting specified) | 13kΩ or more | Voltage pulse input DC0/12V or DC0/24V (common to all CHs) | 100μA or less | Accuracy: ±4% OF READING | 50Hz±2Hz or 60Hz±2Hz | 1 point | 85V~242V AC | 1/2 cycle of load power supply cycle | 31 units | 1 cycle of load power supply cycle | 16 points | 100mA | DC8~30V | DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) | 0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) 1/2 cycle of load power supply cycle (when control method is input synchronous method) | Half-duplex step synchronization type | 0.5V or less (at allowable load current) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.