Absolute humidity
Accessories
Alarm output
Applicable load Zero cross control
Applicable load phase control
Base up setting (output bias)
Control method
Control power supply voltage
Cooling method
Frequency fluctuation
Gradient setting
Heater burnout alarm, current limiter, constant current control
Input sampling period
Input signal
Installation method
Insulation resistance
Leakage current when output is OFF
Manual configuration
Minimum load current
Output limiter (lower limit)
Output limiter (upper limit)
Output limiter at startup (upper limit)
Output limiter time at startup
Output voltage range
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power frequency
Power supply voltage for load
Rated current
Part Number
THV-10PZ150-5*NA-9Handling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Absolute humidity | Accessories | Alarm output | Applicable load Zero cross control | Applicable load phase control | Base up setting (output bias) | Control method | Control power supply voltage | Cooling method | Frequency fluctuation | Gradient setting | Heater burnout alarm, current limiter, constant current control | Input sampling period | Input signal | Installation method | Insulation resistance | Leakage current when output is OFF | Manual configuration | Minimum load current | Output limiter (lower limit) | Output limiter (upper limit) | Output limiter at startup (upper limit) | Output limiter time at startup | Output voltage range | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power frequency | Power supply voltage for load | Rated current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | MAX.W.C 29g/m3 dry air at 101.3kPa | Input/output connector (plug side) included | 1 point alarm output *Input/output connectors are required as accessories. | Resistive load | Resistive load, transformer primary side control | -9.9~100.0% (front key) | Phase control/zero cross control method (Factory: Phase control) | AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V | Natural cooling | Load power supply voltage 50Hz±1Hz, 60Hz±1Hz Control power supply voltage 50Hz±2Hz, 60Hz±2Hz | 0.0~200.0% (front key) 0~100% [External setting device (volume)] | No function | 0.5 cycle of power supply cycle | DC0~10V | Vertical mounting | Between main circuit terminal, control power supply terminal and heatsink: 20MΩ or more, DC500V Between main circuit terminal, heatsink and input terminal: 20MΩ or more, DC500V Between control power supply terminal and input terminal: 20MΩ or more, DC500V | Approx. AC27mA (Load voltage 200V rms 60Hz Ta=25℃) | 0.0~100.0% (front key) 0~100% [External setting device (volume)] | 1A (at 98% output of rated voltage) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0~600 seconds (front key) | 0~98% of load power supply voltage | 5~95%RH (no condensation) | -15~+55℃ (guaranteed operation range) | 12.5VA or less (at AC100V) Inrush current 21A or less 22.0VA or less (at AC240V) Inrush current 55A or less | 50/60Hz shared (automatic detection) | AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V | AC150A |