All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
10.6hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Adaptive sensor
Alarm output
Analog output
Basic type
Bottom hold
Communication function
Display digits
Display update cycle
Dustproof and waterproof structure
Effect of ambient temperature
External dimensions
Factory settings
Input accuracy
Input display
Input impedance
Input method
Inrush current
Insulation resistance
Mass
Memory backup
Operation when wire is disconnected
Peak hold
Permissible ambient temperature
Power consumption
Power supply voltage
Power supply voltage (rated)
Pressure sensor shunt resistance
Sampling period
Sensor supply power
Withstand voltage
Part Number
PG500A4*N-N-5NHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Adaptive sensor | Alarm output | Analog output | Basic type | Bottom hold | Communication function | Display digits | Display update cycle | Dustproof and waterproof structure | Effect of ambient temperature | External dimensions | Factory settings | Input accuracy | Input display | Input impedance | Input method | Inrush current | Insulation resistance | Mass | Memory backup | Operation when wire is disconnected | Peak hold | Permissible ambient temperature | Power consumption | Power supply voltage | Power supply voltage (rated) | Pressure sensor shunt resistance | Sampling period | Sensor supply power | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Strain gauge type sensor | No alarm output | No analog output function | Standard specifications | Retains the minimum measured value *The retained data will be initialized by turning off the instrument power or performing a reset operation. | RS-485 | 5 digits (most significant digit is -1 or 1) | 0.1~10.0 seconds | IP66, NEMA4X (Front direction only when mounting on panel) | Input: ±0.006% of input span/℃ Sensor power supply: ±0.013% of output span/℃ | 48×96×60mm (width x length x depth) | None | ±0.1% of input span | 3 points | 1MΩ or more | No-voltage contact input (OPEN: 500kΩ or more, CLOSE: 500Ω or less) | 12A or less | Between measurement terminal and ground 500V DC 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more | Approximately 200g | Data retained by FRAM (approximately 10 years) Number of rewrites: Approximately 10 billion times | Upscale (downscale can be selected) | Retains the maximum measured value *The retained data will be initialized by turning off the instrument power or performing a reset operation. | -10~50℃ | 10VA or less (at 240V) | AC100~240V | AC100~240V / AC24V / DC24V | 40.0~100.0% *When using pressure sensor with built-in resistance for sensitivity adjustment | 0.1 seconds | DC7.7V±3% DC30mA or less | Between measurement terminal and ground 1,500V DC for 1 minute Between power terminal and ground: DC1,500V for 1 minute |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.