All Categories

History

Paperless recorder VGR-B100-RKC INSTRUMENT

Price (excluding tax)

Estimate Required


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Allowable input wire resistance (resistance temperature detector)

Arithmetic function

Burnout function

Data format

Data recording cycle

Display

Display color

Display group

Display language

Display update cycle

Effect of signal source resistance (thermocouple input)

External recording medium

F value calculation function

Input circuit

Input type

Input/output function (optional)

Internal memory

Main record

Measurement period

Number of analog input points

Other recorded data

PV digital filter

RS-485 communication function (optional)

Recording capacity

Recording method

Scalable range

Square root calculation function

Sub record

Trend data

Unit symbol

See all 10 models in list
  • Part Number

    VGR-B103-60

Share this product


520+ people viewing

Last viewed: 9 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Paperless recorder VGR-B100 VGR-B103-60's performance table

Image Price (excluding tax) Allowable input wire resistance (resistance temperature detector) Arithmetic function Burnout function Data format Data recording cycle Display Display color Display group Display language Display update cycle Effect of signal source resistance (thermocouple input) External recording medium F value calculation function Input circuit Input type Input/output function (optional) Internal memory Main record Measurement period Number of analog input points Other recorded data PV digital filter RS-485 communication function (optional) Recording capacity Recording method Scalable range Square root calculation function Sub record Trend data Unit symbol
Paperless recorder VGR-B100-Part Number-VGR-B103-60 Available upon quote 5Ω or less per wire Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector No input/output function Approximately 100MB Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. 100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel RS-485 communication available SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.

There are 10 models for this product.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Data Loggers Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree