All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Analog output
Applicable standards
Bottom hold
Communication
Digital filter
Display digits
Dust-proof/splash-proof structure
Effects of power outage
External contact input
External power supply (for LED drive/sensor supply)
Factory settings
Flashing display function
Input impedance
Inrush current
Insulation resistance
Mass
Memory backup
PV bias
PV ratio
Peak hold
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power supply voltage
Sampling period
Withstand voltage
Part Number
AG500-4*N-N-N-1-5NProduct
Digital indicator AG500Handling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Alarm output | Analog output | Applicable standards | Bottom hold | Communication | Digital filter | Display digits | Dust-proof/splash-proof structure | Effects of power outage | External contact input | External power supply (for LED drive/sensor supply) | Factory settings | Flashing display function | Input impedance | Inrush current | Insulation resistance | Mass | Memory backup | PV bias | PV ratio | Peak hold | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power supply voltage | Sampling period | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | No alarm output | DC 0~10mV | UL/cUL standards, CE mark, RCM mark | Holds the minimum value of the measured value. *Can be reset by key operation/external contact/communication *Hold value backup is not possible when the instrument power is OFF. | RS-485 | 0.0~100.0 seconds (digital filter OFF when set to 0.0) | 5 digits (most significant digit is -1 or 1) | Dustproof/splashproof structure: IP66 NEMA4X *However, only in the front direction when installing the panel. | Operation is not affected by power outages of 20msec or less. However, any further power outage will return to the initial state. | No external contact input | No external power supply | None | Flashing display when input error or event occurs *Events 1 to 6 can be individually specified. | High voltage input: about 1MΩ Temperature/low voltage input: Approximately 1MΩ or more Current input: approx. 50Ω | 12A or less | Between measurement terminal and ground 500V DC 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal 500V DC 20MΩ or more | Approximately 190g | Data retained by FRAM (approximately 10 years) *Number of rewrites: Approximately 10 billion times | -Input span~+Input span | 0.500~1.500 | Holds the maximum value of the measured value. | 5~95%RH (no condensation) Absolute humidity: MAX.W.C29g/m3 dry air at 101.3kPa | -10~50℃ | 7.0VA or less at AC100V 10.8VA or less at AC240V | AC100~240V | 0.25 seconds | Between measurement terminal and ground: AC1500V for 1 minute Between power terminal and ground: AC1500V for 1 minute |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.