All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Analog output
Applicable standards
Body color
CE marking
Communication function or contact input
Effects of power outage
First alarm
Input/range
Insulation resistance
Limit operation
Limit operation output
Mass
Measurement accuracy
Memory backup
Operation when input is disconnected
Output
PV bias
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Sampling period
Second alarm
Type
Waterproof dustproof
Withstand voltage
Part Number
CB100LK01-M*NN-N-NN/AProduct
Limit controller CB100LHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Analog output | Applicable standards | Body color | CE marking | Communication function or contact input | Effects of power outage | First alarm | Input/range | Insulation resistance | Limit operation | Limit operation output | Mass | Measurement accuracy | Memory backup | Operation when input is disconnected | Output | PV bias | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Sampling period | Second alarm | Type | Waterproof dustproof | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | No analog output | FM:FM3545 UL: UL61010-1 cUL: CAN/CSA-22.2 NO.61010-1 | Black tone | Low voltage directive: EN61010-1 EMC Directive: EN61326-1 RoHS Directive: EN IEC 63000 | No function | Operation is not affected by power outages of 20ms or less Initial state for more than that | No alarm function | Thermocouple: K 0~200℃ | Between measurement terminal and ground 500V DC 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more | Upper limit control: Holds the output when the measured value exceeds the set value. Output can be reset by front key operation, communication, or external contact input. | 1a contact, AC250V 3A (resistive load), non-excited output | Approximately 170g | ± (0.3% of display value + 1 digit) or ±2℃ | Backed up by non-volatile memory (Number of writes: approximately 1 million times, data retention period: approximately 10 years) | Upscale | Relay contact output | When inputting temperature: -1,999 (-199.9) ~9,999 (999.9) ℃ DC voltage/current input: -span~+span | 45~85%RH (no condensation) | 0~50℃ | AC100~240V specifications: 10VA or less AC24V specification: 5VA or less DC24V specification: 160mA or less | 0.5 seconds | No alarm function | Limit controller | No waterproof/dustproof structure | Between measurement terminal and ground: AC1000V for 1 minute Between power terminal and ground: AC1500V for 1 minute |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.