All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
10.1hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm 1 type
Alarm 2 type
Applicable standards
CE/UKCA marking
Digital filter
Effects of power outage
Input/range
Mass
Measurement accuracy
Memory backup
Number of output points
Option
Other applicable standards
Other conditions
Output 1
Output 2
Output allocation
Output content
PV bias
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power supply voltage
Relay contact output Contact capacity
Relay contact output Contact method
Relay contact output electrical life
Sampling period
Type
Usage atmosphere
Waterproof and dustproof
Part Number
SA100LK01-MN-3*NN-NN/02Product
Limit controller SA100LHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Alarm 1 type | Alarm 2 type | Applicable standards | CE/UKCA marking | Digital filter | Effects of power outage | Input/range | Mass | Measurement accuracy | Memory backup | Number of output points | Option | Other applicable standards | Other conditions | Output 1 | Output 2 | Output allocation | Output content | PV bias | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power supply voltage | Relay contact output Contact capacity | Relay contact output Contact method | Relay contact output electrical life | Sampling period | Type | Usage atmosphere | Waterproof and dustproof |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | No alarm function | No alarm function | UL: UL 61010-1 cUL: CAN/CSA-C22.2 No.61010-1 | Electrical safety: EN61010-1 EMC: EN61326-1 RoHS: EN IEC 63000 | 1~100 seconds (When set to 0: OFF) | Power outages of 20msec or less will not affect operation. | Thermocouple: K (JIS/IEC) 0~200℃ | Approximately 110g | Thermocouple: ± (1% of display value + 1 digit) or ±2℃ (within whichever is greater) | Data backup using non-volatile memory (Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years) | 2 points (Output 1 (OUT1), Output 2 (OUT2)) | No optional features | RCM: EN55011 FM:FM3545 | No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. | Relay contact output | No output | Output 1 Limit output (de-energized) Output 2 Logic AND output of 1st and 2nd alarms (excited) | Output 1 (OUT1): Relay contact output or current output Output 2 (OUT2): No output or relay contact output *Output type is fixed at the time of order and cannot be changed after purchase. | -span~+span (within -1,999~+9,999digit) | 45~85%RH (no condensation) Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa | 0~50℃ | AC24V specifications: maximum 4VA DC24V specification: max. 100mA | AC/DC 24V | AC 240V 3A (resistive load) DC 30V 1A (resistive load | 1c contact | 300,000 times or more (AC 240V 2A DC 30V 1A) More than 200,000 times (AC 240V 3A) | 0.5 seconds (switchable to 0.25 seconds) | Limit controller | There shall be no corrosive or flammable gas, and there shall be no heavy dust. | No waterproof/dustproof structure |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.