All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Communication speed
Connection method
Control operation
Digital output
Insulation resistance
Level PID Number of levels
Level automatic setting
Level setting range
Loader communication Number of communication points
Measurement input/range
Number of program memories
Number of segment memories
Option 1 feature
Option 2 features
Output 1 (OUT1) type
Output 2 (OUT2) type
Pattern end output time
Pattern repeat execution count
Power consumption/current
Power supply voltage
Protocol
Sampling period
Segment time
Specifying factory settings
Time signal output function Output destination
Time signal output function points
Wait function Setting range Wait zone lower side
Wait function Setting range Wait zone upper side
Waterproof/dustproof structure
Withstand voltage
Part Number
PZ400FK01-VN3*1NN1/NHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Communication speed | Connection method | Control operation | Digital output | Insulation resistance | Level PID Number of levels | Level automatic setting | Level setting range | Loader communication Number of communication points | Measurement input/range | Number of program memories | Number of segment memories | Option 1 feature | Option 2 features | Output 1 (OUT1) type | Output 2 (OUT2) type | Pattern end output time | Pattern repeat execution count | Power consumption/current | Power supply voltage | Protocol | Sampling period | Segment time | Specifying factory settings | Time signal output function Output destination | Time signal output function points | Wait function Setting range Wait zone lower side | Wait function Setting range Wait zone upper side | Waterproof/dustproof structure | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 38,400bps | Front connector: COM-K2 and dedicated cable (W-BV-03-1500) | PID operation with AT (reverse operation) | Digital output 1 point | Between measurement terminal and ground: DC 500V 20MΩ or more Between power terminal and ground: DC 500V 20MΩ or more | 8 levels (set in level settings 1 to 7) | Function to automatically calculate level PID setting value | Input range lower limit ~ input range upper limit | 1 point (front loader) | Thermocouple: K 0~200℃ | Up to 16 patterns | Maximum of 16 segments *Maximum of 256 segments with pattern link With hold and step functions | No optional features | None | Voltage pulse output for SSR drive | No output 2 | 0 hours 0 minutes to 199 hours 59 minutes or 0 minutes 00 seconds to 199 minutes 59 seconds *Continues ON when set to 0 | 1~1,000 times *Execute infinite times with 1,000 setting | AC 24V specification: Maximum 6.9VA (at AC 24V) Inrush current 16.3A or less DC 24V specification: Maximum 175mA (DC 24V) Inrush current 11.5A or less | AC/DC24V | RKC standard (ANSI X3.28-1976 subcategory 2.5 A4 compliant) | 0.05 seconds | 0 hours 0 minutes to 199 hours 59 minutes or 0 minutes 0 seconds to 199 minutes 59 seconds *Infinite time available | None | DO1~4 | 4 points (TS1~TS4) | *0 (0.0, 0.00) Setting: Weight zone lower side OFF Thermocouple/RTD input: -200~0℃, -200.0~0.0℃ or -input span~0.00℃ Voltage/current input: -100.0~0.0% of input span | *0 (0.0, 0.00) Setting: Weight zone upper side OFF Thermocouple/RTD input: 0~200℃, 0.0~200.0℃ or 0.00~input span Voltage/current input: 0.0~100.0% of input span | Waterproof and dustproof structure (IP65) | Between measurement terminal and power supply terminal 3,000V AC for 1 minute Between measurement terminal and ground 1,500V AC for 1 minute Between power terminal and ground 1,500V AC for 1 minute |