You can search for other models from each index. The displayed value is the value of the currently selected part number.
CT input 1 (CT input of channel 1)
CT input 2 (CT input of channel 2)
Control method
Control output 1 (channel 1)
Control output 2 (channel 2)
Control response
Control setting range Proportional band (P)
Current consumption
Differential time (D)
Effect of signal source resistance
Effects of power outage
Influence of permissible input conductors
Input digital filter
Insulation resistance
Integral time (I)
Level PID
Mass
Measuring input (channel 1)
Measuring input (channel 2)
Number of input points
Operation when input is disconnected
Output change rate limiter
Output limiter
PV bias
Permissible ambient temperature
Power supply voltage
Proportional period
Sampling period
Type
Withstand voltage
Part Number
X-TIO-A-KK-MV*NNHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | CT input 1 (CT input of channel 1) | CT input 2 (CT input of channel 2) | Control method | Control output 1 (channel 1) | Control output 2 (channel 2) | Control response | Control setting range Proportional band (P) | Current consumption | Differential time (D) | Effect of signal source resistance | Effects of power outage | Influence of permissible input conductors | Input digital filter | Insulation resistance | Integral time (I) | Level PID | Mass | Measuring input (channel 1) | Measuring input (channel 2) | Number of input points | Operation when input is disconnected | Output change rate limiter | Output limiter | PV bias | Permissible ambient temperature | Power supply voltage | Proportional period | Sampling period | Type | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | No CT input | No CT input | Brilliant PID control (with auto tuning function) Direct action/reverse action switchable | Relay contact output | Voltage pulse output DC0/12V | Slow, Medium, Fast | During temperature input 0~input span (℃) When inputting voltage/current: 0.0~1,000.0% of input span | 120mA or less | 0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) | 0.25μV/Ω (thermocouple input) | No effect on power outages of 20ms or less For more than that, you can choose between hot start 1/2 and cold start 1/2. | Maximum 10Ω per wire (resistance temperature detector input) | 0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) | Between each insulation block DC 500V 20MΩ or more | 0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) | Select 8 types of PID parameters depending on the position of the set value | 220g | Input type: K Range: -200~1,372℃ | Input type: K Range: -200~1,372℃ | 2 points (channel-to-channel isolation) *Second input can be used as remote input. | Upscale | 0.0~100.0%/sec | -5.0~+105.0% (set by upper and lower limits) | ±input range span | -10~50℃ | DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) | 0.2~50.0 seconds | 0.025 seconds | Basic type | AC 600V for 1 minute between each insulation block |