■Temperature control module This is a module for temperature control. Two types of input can be selected: thermocouple and resistance temperature detector, and two types of control points can be selected: 1 or 2 points. Thermocouple/RTD input: 1 point, brilliant PID or two-position control, CT input: 1 point, alarm output: 1 point, sampling period: 0.5 seconds
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Cold junction temperature compensation error
Control calculation cycle
Control method
Control response parameters
Differential time
Effect of allowable input conductor resistance
Effect of external resistance
External dimensions
FAIL lamp
Heating side proportional band
Input filter
Input impedance
Input type
Integration time
Manual setting function Auto/manual switching
Manual setting function Setting range
Measurement accuracy
Number of input points
Operation (RUN) lamp
Operation when self-diagnosis error occurs
Other functions
PV bias
Resolution
Sampling period
Self-diagnosis function check items
Sensor current
Weight
When input is disconnected
Cooling side proportional band
Overlap/dead band
Part Number
H-TIO-AHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Cold junction temperature compensation error | Control calculation cycle | Control method | Control response parameters | Differential time | Effect of allowable input conductor resistance | Effect of external resistance | External dimensions | FAIL lamp | Heating side proportional band | Input filter | Input impedance | Input type | Integration time | Manual setting function Auto/manual switching | Manual setting function Setting range | Measurement accuracy | Number of input points | Operation (RUN) lamp | Operation when self-diagnosis error occurs | Other functions | PV bias | Resolution | Sampling period | Self-diagnosis function check items | Sensor current | Weight | When input is disconnected |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Within ±1.0℃ (0~50℃ range) However, if the input value is -100℃~-150℃, it will be within ±2.0℃, and if the input value is -150℃~-200℃, it will be within ±3.0℃. *Thermocouple input only | 0.5 seconds | Two position control Brilliant PID control *PI control is also possible | Can be set in 3 stages: Slow, Medium, Fast | 1~3,600 seconds *Differential time 0 seconds: PI control | 20Ω or less RTD input only | Approx. 0.35μV/Ω *Thermocouple input only | 24 (W) ×96 (H) ×100 (D) mm | Red LED: Lights up when temperature control module is abnormal | 0.1%~1,000.0% of span | 1st order lag digital filter Time constant can be set from 1 to 100 seconds *If set to 0 seconds, the filter will be OFF. | 1MΩ or more *Thermocouple input only | Thermocouple/RTD input | 1~3,600 seconds | Temperature control can be selected automatically (auto) or manually (manual) | -5.0~105.0% | ±0.3% of span ±1digit *However, 0 to 399℃ for thermocouple B input is not covered by the system guarantee. | 1 point | Green LED: Blinks when temperature control module is operating | FAIL lamp lights up Control output OFF Reset state | With overshoot prevention function (RFB limiter method) With enhanced auto tuning function | -5.00~+5.00% of span | 1 or 0.1℃ | 0.5 seconds | RAM check Adjustment data check Input value check watchdog timer | Approx. 0.25mA *Resistance temperature sensor input only | 120g | Upscale |