All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
10.1hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Applicable standards
CT input
Effect of external resistance (thermocouple input)
Effects of power outage
Factory settings
Input type
Mass
Memory backup
Number of input points
Number of memory areas
Number of output points
Operation when input wire is disconnected
Output 1
Output 2
Output 3
Output 4
Permissible ambient humidity
Permissible ambient temperature
Power consumption (at maximum load)
Power supply voltage
RoHS Directive
Sampling period
Type
Wiring method
Part Number
Z-TIO-AT-MMM4/NNHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Applicable standards | CT input | Effect of external resistance (thermocouple input) | Effects of power outage | Factory settings | Input type | Mass | Memory backup | Number of input points | Number of memory areas | Number of output points | Operation when input wire is disconnected | Output 1 | Output 2 | Output 3 | Output 4 | Permissible ambient humidity | Permissible ambient temperature | Power consumption (at maximum load) | Power supply voltage | RoHS Directive | Sampling period | Type | Wiring method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | CE marking compliant, UL, cUL certified product, RCM marking compliant | None | Approximately 0.125μV/Ω | No effect for 4msec or less *For Z-TIO modules, STOP start and hot/cold start can be selected for more than that. | None (control operation, input range, and initial settings are not specified) | Thermocouple: K Range: -200.0~+1,372.0℃ | Approximately 160g | Data backup using non-volatile memory (FRAM) Number of rewrites: Approximately 10 billion times or more Data storage retention period: Approximately 10 years | 4 points or 2 points (isolated between inputs) | 8 points (each channel, independent setting) | 4 points | Upscale or downscale can be selected | Relay contact output | Relay contact output | Relay contact output | Continuous voltage output DC0~5V | 5~95%RH *Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa | -10~+50℃ | Maximum 140mA (DC24V) Inrush current 10A or less | DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) | Already supported | 0.25 seconds | 4CH temperature control module Standard type | Terminal block type |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.