All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm 1 type
Alarm 2 type
Alarm 3 types
Communication function
Control operation
Effect of external resistance
Effect of input lead resistance
Effects of power outage
External contact input
External dimensions
Input filter
Input/range
Insulation resistance
Mass
Memory backup
Number of input points
Operation when input wire is disconnected
Other conditions
Output 1 (control output)
Output 2 (alarm 3 channel individual output)
PV bias
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power supply voltage
Sampling period
Type
Usage atmosphere
Waterproof dustproof
Withstand voltage
Part Number
MA900-4FK01-MN-3*ANN-N1/1Handling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Alarm 1 type | Alarm 2 type | Alarm 3 types | Communication function | Control operation | Effect of external resistance | Effect of input lead resistance | Effects of power outage | External contact input | External dimensions | Input filter | Input/range | Insulation resistance | Mass | Memory backup | Number of input points | Operation when input wire is disconnected | Other conditions | Output 1 (control output) | Output 2 (alarm 3 channel individual output) | PV bias | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power supply voltage | Sampling period | Type | Usage atmosphere | Waterproof dustproof | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Upper limit deviation alarm | No alarm function | No alarm function | RS-232C (RKC standard communication) | PID control with AT (reverse action) | Approximately 0.2μV/Ω | Approximately 0.01 (%/Ω) of reading (within 10Ω maximum per line) | No effect on power outages of 30ms or less Initial state for more than that | No contact input | 96×96×100mm (width x length x depth) | 1st order lag digital filter Time constant: Can be set from 1 to 100 seconds (OFF at 0 seconds) | Thermocouple: K (JIS/IEC) Range range: 0~200℃ | Between power terminal and ground DC 500V 20MΩ or more Between measurement terminal and ground DC 500V 20MΩ or more | Approximately 560g | Data backup using non-volatile memory (data storage retention period: approximately 10 years, number of rewrites: approximately 100,000 times) | 4 points | Upscale | No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. | Relay contact output | No output | ±Setting span However, within -1,999 (-199.9) ~+9,999 (+999.9℃) digits | 45~85%RH (no condensation) | 0~50℃ | AC24V specifications: max. 11VA DC24V specification: max. 330mA | AC/DC24V | 0.5 seconds | 4ch | No corrosive or flammable gases, and no heavy dust. | Waterproof and dustproof structure available | Between power terminal and ground: AC 1,500V for 1 minute Between measurement terminal and ground: AC 1,000V for 1 minute |