History
Price (excluding tax)
Response Rate
100.0%
Response Time
10.1hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Applicable standards
Case color
Digital filter
Effect of signal source resistance
Effects of power outage
Error during close instrumentation
Influence of permissible input conductors
Inrush current
Insulation resistance
Link destination area number setting
Mass
Multi-memory area function Number of areas
Operation when input wire is disconnected
Optional features
Output 1 (OUT1)
Output 2 (OUT2)
Output type
PV bias
PV ratio
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power supply voltage
Sampling period
Size
Soak time setting
Specifying factory settings
Square root calculation function
Usage atmosphere/conditions
Withstand voltage
Part Number
FB100-MN-3*C/NNHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Applicable standards | Case color | Digital filter | Effect of signal source resistance | Effects of power outage | Error during close instrumentation | Influence of permissible input conductors | Inrush current | Insulation resistance | Link destination area number setting | Mass | Multi-memory area function Number of areas | Operation when input wire is disconnected | Optional features | Output 1 (OUT1) | Output 2 (OUT2) | Output type | PV bias | PV ratio | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power supply voltage | Sampling period | Size | Soak time setting | Specifying factory settings | Square root calculation function | Usage atmosphere/conditions | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | CE marking compliant, UL, cUL certified product, RCM marking compliant | White tone | Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds) | 0.2μV/Ω (thermocouple input) | No effect on power outages of 20ms or less For more than that, hot start or cold start can be selected. | ±1.5℃ | 0.01%/Ω or less (RTD input) *However, maximum 10Ω per wire | Maximum 12A or less | Between measurement terminal and ground: DC 500V 20MΩ or more Between power terminal and ground: DC 500V 20MΩ or more Between measurement terminal and power supply: DC 500V 20MΩ or more | 1~8 (No link if set to 0) | Approximately 150g | 8 points | Upscale/Downscale *Switchable | 2 digital inputs + opening feedback resistance input | Relay contact output | No output 2 | 1a contact Rating: AC250V 3A DC30V 1A (resistive load) Electrical life: 100,000 times or more (rated load) | ±input range span | 0.500~1.500 | 5~95% (no condensation) *Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa | -10~+50℃ | AC24V specifications: max. 5.3VA DC24V specification: max. 142mA | AC/DC24V | 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) | 48×48mm | ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds ・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes *Selectable | None | Arithmetic formula: PV=√ (input value x PV ratio + PV bias) Low level cutoff: 0.00~25.00% of span | No corrosive or flammable gases, and no heavy dust. No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. | Between measurement terminal and ground: AC 1,500V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute Between measurement terminal and power supply: AC 2,300V for 1 minute |