All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
9.8hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Control operation
Cooling side output
Data backup
Effect of external resistance
Effect of input lead resistance
Effects of power outage
First alarm
Heating side output
Input type
Insulation resistance
Operation when input wire is disconnected
Other conditions
Output
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Range
Sampling period
Second alarm
Size
Usage atmosphere
Weight
Withstand voltage
Part Number
C100FK01-M*NCHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Control operation | Cooling side output | Data backup | Effect of external resistance | Effect of input lead resistance | Effects of power outage | First alarm | Heating side output | Input type | Insulation resistance | Operation when input wire is disconnected | Other conditions | Output | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Range | Sampling period | Second alarm | Size | Usage atmosphere | Weight | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | With AT PID operation (reverse operation) | No cooling side output | Data backup using non-volatile memory | Approx. 0.35μV/Ω (thermocouple input) | Approximately 0.01 (%/Ω) of reading (RTD input) *However, maximum 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | No alarm | Relay contact output | K | Between measurement terminal and ground terminal: DC500V 20MΩ or more Between power supply terminal and ground terminal 500V DC 20MΩ or more | Upscale (downscale can be specified) | No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. | AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load | 45~85%RH | 0~+50℃ (32~122℉) | AC specifications: 17VA or less AC24V specification: 7.5VA or less DC specifications: DC24V 200mA or less | 0~200℃ | 0.5 seconds | Upper and lower limit deviation alarm | 48×48mm | No corrosive or flammable gases, and no heavy dust. | Approximately 170g | Between measurement terminal and ground terminal: AC1,000V for 1 minute Between power supply terminal and ground terminal: AC1,500V for 1 minute |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.