All Categories
History
Price (excluding tax)
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Accuracy at 25℃ (bar)
Allowable load
Allowable pressure (static pressure) (bar)
Allowable voltage
Body width across flats 24mm
Connection (screw)
Diaphragm
Fixed hysteresis
Gold plated contacts
Housing material
Material
Maximum current
Maximum cycle rate
Maximum hysteresis at 25°C
Measurement method
Mechanical life
Option-1
Option-2
Pressure range (bar)
Protection class
Silver plated contacts
Switch specifications
Temperature range
Test
Usable voltage
Part Number
PMM150Handling Company
LCI Co., Ltd.Categories
Image | Price (excluding tax) | Accuracy at 25℃ (bar) | Allowable load | Allowable pressure (static pressure) (bar) | Allowable voltage | Body width across flats 24mm | Connection (screw) | Diaphragm | Fixed hysteresis | Gold plated contacts | Housing material | Material | Maximum current | Maximum cycle rate | Maximum hysteresis at 25°C | Measurement method | Mechanical life | Option-1 | Option-2 | Pressure range (bar) | Protection class | Silver plated contacts | Switch specifications | Temperature range | Test | Usable voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | ±5 | 0.5 (0.2) A | Galvanized steel: 300 SUS316 equivalent: 300 | DC/AC 48V | 〇 | R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) | NBR (-5~+60℃) FKM (-5~+90℃) (optional) Silicon (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) | 〇 | 〇 | PA (polyamide) | Brass (brass) galvanized carbon steel SUS316 (equivalent) | <30mA, 0.5A | 80 times/min | 10 | Piston type | 10^6 (number of operations) | With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) | Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid For Cap3 connection | 50~150 | IP00 (main body) IP65 (when using Cap3) IP54 (when using Cap1) IP67 (optional) (when using Cap14) | 〇 | NO (normally open), NC (normally closed) | -40~+140℃ (depending on diaphragm/gasket material) | 1,500V, 10mA, 10 seconds | DC12V, DC24V, DC48V |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
17.3hrs
Company Review
4.0