All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Cooling
Dimensions (L×W×H)
Frequency
Humidity
Input low voltage warning
Input voltage range
Maximum efficiency (1/3 load)
No-load power
Nominal input voltage
Nominal output voltage
Operating temperature range
Output waveform
Protection circuit
Rated output power
Standard efficiency (rated load)
Surge power
Weight
Part Number
XP250J-66, XP250K-66Product
DC-AC inverter XP series XP250Handling Company
Denryo Co., Ltd.Categories
Image | Price (excluding tax) | Cooling | Dimensions (L×W×H) | Frequency | Humidity | Input low voltage warning | Input voltage range | Maximum efficiency (1/3 load) | No-load power | Nominal input voltage | Nominal output voltage | Operating temperature range | Output waveform | Protection circuit | Rated output power | Standard efficiency (rated load) | Surge power | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | Natural convection | 274×134×72mm | J=50Hz±0.1%, K=60Hz±0.1% | 5~95%RH (no condensation) | 58.5Vdc | 57.5~91Vdc | 90% | 6W or less | 66Vdc | 100Vac±6% | -25~+30℃ (rated load), output will be reduced by 20% for every 10℃ rise above 30℃. | Sine wave (distortion rate 1.5% standard, max. 2%) | Input undervoltage, input overvoltage, output overload, output short circuit, overtemperature | 210W | 88% | 250W | 2.3kg |