Part Number
XP600J-12, XP600K-12Product
DC-AC inverter XP series XP600Handling Company
Denryo Co., Ltd.Categories
Image | Price (excluding tax) | Cooling () | Dimensions (L×W×H) () | Frequency () | Humidity () | Input low voltage warning () | Input voltage range () | Maximum efficiency (1/3 load) () | No-load power () | Nominal input voltage () | Nominal output voltage () | Operating temperature range () | Output waveform () | Protection circuit () | Rated output power () | Standard efficiency (rated load) () | Surge power () | Weight () |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Heat activated fan | 307×195×91mm | J=50Hz±0.1%, K=60Hz±0.1% | 5~95%RH (no condensation) | 10.6Vdc | 10.4~16.5Vdc | 87% | 8W or less | 12Vdc | 100Vac±6% | -25~+30℃ (rated load), output will be reduced by 20% for every 10℃ rise above 30℃. | Sine wave (distortion rate 1.5% standard, max. 2%) | Input undervoltage, input overvoltage, output overload, output short circuit, overtemperature | 510W | 85% | 1,000W | 3kg |