All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
58.4hours
You can search for other models from each index. The displayed value is the value of the currently selected part number.
AC input selection frequency
AC input synchronous frequency
AC input voltage range
Breaker
Cooling
Current consumption (power save mode)
DC input voltage range
Dimensions (L×W×H)
Frequency (switchable)
Input protection circuit
Insulation resistance
Maximum efficiency
Maximum output power (3 seconds)
No load current
Operating temperature range
Output power (3 minutes)
Output protection circuit
Output voltage (switchable)
Output waveform
Pressure resistance
Rated input voltage
Rated output power
Storage temperature/humidity range
Surge power (0.2 seconds or less)
Uninterrupted switching time
Vibration resistance
Weight
E mark
EMC standard
Safety standards
Part Number
SD3500-148Product
DC-AC inverter SD series SD3500Handling Company
Denryo Co., Ltd.Categories
Image | Price (excluding tax) | AC input selection frequency | AC input synchronous frequency | AC input voltage range | Breaker | Cooling | Current consumption (power save mode) | DC input voltage range | Dimensions (L×W×H) | Frequency (switchable) | Input protection circuit | Insulation resistance | Maximum efficiency | Maximum output power (3 seconds) | No load current | Operating temperature range | Output power (3 minutes) | Output protection circuit | Output voltage (switchable) | Output waveform | Pressure resistance | Rated input voltage | Rated output power | Storage temperature/humidity range | Surge power (0.2 seconds or less) | Uninterrupted switching time | Vibration resistance | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 50/60Hz | 47~57/53~63Hz | 100/110/115/120Vac±12.5% | 35A | Temperature load linked fan | 0.5A | 40.0~64.0Vdc | 496×283×128mm | 50/60 (initial value) Hz±0.1% | Undervoltage, overvoltage, reverse polarity connection (fuse), AC input overcurrent (breaker) | 100MΩ/500Vdc | 91% | 4,500~6.4000VA | <0.8A | -20~+60℃ | 3,500~4,500VA | Overload, short circuit, overtemperature, overvoltage | 100 (initial value) /110/115/120Vac±3% | Sine wave (distortion rate 3% or less) | Battery Input – AC Output: 2,121Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 1,414Vdc | 48Vdc | 3,500VA | -40~+70℃/0~90%RH (no condensation) | >6,000VA | Less than 4msec when used alone, less than 6msec when operated in parallel | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 10kg |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
58.4hrs