All Categories
History
Price (excluding tax)
■Lightmaster Pro L-478D is equipped with Elinchrome's flash wireless control system. The Light Master Pro -478DR-EL is a light meter based on the L-478D that incorporates the EL Skyport system, Elinchrome's flash radio control system. Flash emission and dimming compatible with Elinchrome's EL Skyport system can be controlled from the light meter. This allows you to control the light intensity of the flash from the position where you measured the exposure, and eliminates the hassle of attaching and detaching the transmitter from the camera, dramatically improving your workflow using the flash. Compatible with Elinchrome's EL Skyport wireless system (2.4GHz) ■Recommended uses ・Landscape photography ・Studio shooting ・Flower/portrait photography ・School recommendation ■Features ・Built-in EL skyport enables flash light measurement and light intensity adjustment. L-478DR-EL allows you to adjust the flash light intensity up to +/-9.9 steps in 0.1 steps. Since the flash can be fired and measured wirelessly, you can set the desired exposure without having to move. ・It is possible to adjust the light intensity and turn ON/OFF the modeling lamp of the built-in EL skyport flash. ・20 radio channels and 4 groups can be selected - Exposure for each group and exposure when all lights are fired can be displayed on the same screen
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Light receiving method Reflection Receiving angle
Light reception method Incident Oscillation
Light reception method Incident: Photosphere ⇔ Flat plate
Light reception method: Incident/reflection switching
Measurement mode Ambient light Aperture priority
Measurement mode Ambient light Cine camera (f/s priority)
Measurement mode Ambient light HD cine camera
Measurement mode Ambient light Illuminance
Measurement mode Ambient light Luminance
Measurement mode Ambient light Shutter speed Aperture priority
Measurement mode Ambient light Shutter speed priority
Measurement mode Flash light Cord connection/cordless
Measurement mode Flash light integration (MLT)
Measurement range (ISO100) Ambient light Brightness Cd/㎡
Measurement range (ISO100) Ambient light Illuminance Lx
Measurement range (ISO100) Ambient light Incident light EV value
Measurement range (ISO100) Ambient light Reflected light EV value
Measurement range Flash light Incident light F value
Measurement range Flash light Reflected light F value
Model
Setting ISO
Settings Ambient Light Aperture
Settings Ambient light Frame rate
Settings Ambient light Shutter opening angle
Settings Ambient light Shutter speed
Settings Flash light Shutter speed
Measurement mode Flash light Radio trigger
Part Number
L-478DR-ELHandling Company
SEKONIC CORPORATIONCategories
Usage Scenarios
Architecture & Construction Use / Printing & Office Machines UseImage | Price (excluding tax) | Light receiving method Reflection Receiving angle | Light reception method Incident Oscillation | Light reception method Incident: Photosphere ⇔ Flat plate | Light reception method: Incident/reflection switching | Measurement mode Ambient light Aperture priority | Measurement mode Ambient light Cine camera (f/s priority) | Measurement mode Ambient light HD cine camera | Measurement mode Ambient light Illuminance | Measurement mode Ambient light Luminance | Measurement mode Ambient light Shutter speed Aperture priority | Measurement mode Ambient light Shutter speed priority | Measurement mode Flash light Cord connection/cordless | Measurement mode Flash light Radio trigger | Measurement mode Flash light integration (MLT) | Measurement range (ISO100) Ambient light Brightness Cd/㎡ | Measurement range (ISO100) Ambient light Illuminance Lx | Measurement range (ISO100) Ambient light Incident light EV value | Measurement range (ISO100) Ambient light Reflected light EV value | Measurement range Flash light Incident light F value | Measurement range Flash light Reflected light F value | Model | Setting ISO | Settings Ambient Light Aperture | Settings Ambient light Frame rate | Settings Ambient light Shutter opening angle | Settings Ambient light Shutter speed | Settings Flash light Shutter speed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 5° (with optional viewfinder installed) | Left and right (270 degrees) | One-touch switching | Attachment/detachment switching | ○ | ○ | ○ | ○ | ○ (When equipped with a separately sold viewfinder) | ○ | ○ | ○ | ○ | ○ | 1.0cd/㎡~980,000cd/㎡ (with optional viewfinder installed) | 0.63lx~2,000,000lx | EV-2 (F2.0, 15 seconds) ~EV22.9 (F22.9, 1/8,000 seconds) | EV3 (F2.8, 1 second) ~EV22.9 (F22.9, 1/8,000 second) (with optional viewfinder attached) | F1.0~F128.9 (=F161.2) | F2.8~F128.9 (with optional viewfinder installed) | Flash light/steady light meter | 3~409,600 (1/3 step), 850 | F0.5~F161 (1/1/2/1/3 steps) | 1~1,000 (47 steps) *20 settings can be made in user settings | 0.001°~360° *20 settings possible in user settings | 30 minutes ~ 1/64,000 seconds, 1/200, 1/400 (1/1/2/1/3 steps) | 30 minutes ~ 1/1,000 seconds 1/75, 1/80, 1/90, 1/100, 1/200, 1/400 (1/1/2/1/3 steps) |
Reviews shown here are reviews of companies.