All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Communication method
Dimensions (W×H×D)
Dynamic range
EMC requirements
Housing material
Humidity during use and storage
Impact resistance (EN60068-2-27)
Light detection method
Maximum light output
Maximum number of sensors/OC
Maximum total number of sensors
Measuring range
Number of optical connectors (simultaneous data collection)
O.S.A.
Operating temperature, storage temperature
Power connector
Power consumption
Power supply
Protection class (EN60529; IEC529)
Random vibration resistance (EN60068-2-64)
Resolution/Repeatability
Sample rate
Stability/Reproducibility
Synchronization method
Weight
Connector type
Sinusoidal vibration resistance (EN60068-2-6)
Part Number
FS22DIHandling Company
Hottinger Brüel & KjærImage | Price (excluding tax) | Communication method | Dimensions (W×H×D) | Dynamic range | EMC requirements | Housing material | Humidity during use and storage | Impact resistance (EN60068-2-27) | Light detection method | Maximum light output | Maximum number of sensors/OC | Maximum total number of sensors | Measuring range | Number of optical connectors (simultaneous data collection) | O.S.A. | Operating temperature, storage temperature | Power connector | Power consumption | Power supply | Protection class (EN60529; IEC529) | Random vibration resistance (EN60068-2-64) | Resolution/Repeatability | Sample rate | Stability/Reproducibility | Synchronization method | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Ethernet (RJ45), SCPI (ASCII text string) over TCP/IP | Standard: 155 x 125 x 275mm, rack mount type: 483 x 88 x 400mm | >25dB (ratio of the detection limit of the optical power emitted at the optical connector and the optical power reflected by the fiber, Bragg, or grating) | Compliant with EN 61326 | Aluminum | <90% (at 40℃), <95% (non-condensing) | 20g (each axis), 11ms pulse (during the test, the interrogator is powered off. After the test, the correct functionality of the instrument is verified (transport simulation)) | Linear (step selectable) | 1 connector: 3dBm, 4 connectors: -1dBm, 8 connectors: -4.5dBm | 31~127 | 80~600 | 100nm (1,500~1,600) | Either 1, 4, or 8; FC/APC or SC/APC | Yes (Optical spectrum analysis (1S/S refresh rate, 7,050 points per sample, ~15pm resolution)) | 0~50℃, -20~70℃ | Standard type: ODU Medi-Snap S11M08-P04MJGO-5280, Rack mount type: C14 (IEC/EN 60320-1) | Nominal value: 22.5W, standby: 2W | Standard type: 11~36 VDC, Rack mount type: 100~240 VAC (50~60Hz) | Standard: IP40, rack mount type: IP20 | 9g (10Hz~500Hz), power spectral density = 1g^2/Hz (During the test, the interrogator will be powered off. After the test, the correct functionality of the device will be confirmed (transport simulation)) | <1.5pm | 50~1,000S/s (all applicable and selectable at time of use) | 17:00 | NTP method | Standard (not including mounting bracket): 4.5kg, rack mount type: 7kg |
Reviews shown here are reviews of companies.