All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Current (rush) (peak and duration)
Dimensions (WHD)
Isc PV (Absolute Maximum) (Adc)
MPPT tracking accuracy
MPPT tracking range (Vdc)
Maximum DC input current (Adc)
Maximum inverter backfeed current (Adc)
Maximum number of units per branch (20A)
Maximum output fault current (Aac)
Maximum output overcurrent protection (Aac)
Night tare loss (Wp)
Nominal frequency (Hz)
Nominal power grid voltage (Vac)
Overcurrent protection
Overload protection
Overvoltage/undervoltage protection
Peak AC output power (Wp)
Permissible power grid frequency (Hz)
Permissible power grid voltage (Vac)
Power factor (cos phi, fixed)
Rated AC output power (Wp)
Rated output current (Aac)
Recommended maximum DC open circuit voltage (Vdc)
Recommended maximum PV power (Wp)
Remote island prevention protection
Reverse DC polarity protection
THD
Too much or too little frequency protection
Weight
Weighted average efficiency (CEC)
Part Number
BDM 600Product
Microinverter BDM600Handling Company
NORTHERN ELECTRIC AND POWER Co., Ltd.Categories
Image | Price (excluding tax) | Current (rush) (peak and duration) | Dimensions (WHD) | Isc PV (Absolute Maximum) (Adc) | MPPT tracking accuracy | MPPT tracking range (Vdc) | Maximum DC input current (Adc) | Maximum inverter backfeed current (Adc) | Maximum number of units per branch (20A) | Maximum output fault current (Aac) | Maximum output overcurrent protection (Aac) | Night tare loss (Wp) | Nominal frequency (Hz) | Nominal power grid voltage (Vac) | Overcurrent protection | Overload protection | Overvoltage/undervoltage protection | Peak AC output power (Wp) | Permissible power grid frequency (Hz) | Permissible power grid voltage (Vac) | Power factor (cos phi, fixed) | Rated AC output power (Wp) | Rated output current (Aac) | Recommended maximum DC open circuit voltage (Vdc) | Recommended maximum PV power (Wp) | Remote island prevention protection | Reverse DC polarity protection | THD | Too much or too little frequency protection | Weight | Weighted average efficiency (CEC) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 24A, 15us | 10.91´x5.20´x1.97´ | 18x2 | >99.5% | 22-55 | 14x2 | 0 | 7/6/7 | 4.4A peak | 10 | 0.11 | 60/50 | 240/208/230 | Yes | Yes | Yes | 550 | 59.3a 60.5*/configurable | 211V-264*/183V-229*/Configurable | >0.99 (at rated power) | 500 | 2/2.40/2.17 | 60 | 450 x 2 | Yes | Yes | <3% (at rated power) | Yes | 6.4 pounds | 95.50% |
Reviews shown here are reviews of companies.