Alarm contact
Applicable wire
Connection terminal
Exam class
Failure display
Follow current breaking rating N-PE
Follow-on current breaking rating between L-N
Impulse discharge current between L-N
Maximum continuous working voltage Uc
Nominal discharge current In L-N
Protection mode
Recommended wire
Single phase 2 wire 1 wire grounding 100V
Single phase 2 wire 1 wire grounding 200V
Single phase 2 wire neutral point grounding 200V
Single phase 3 wire neutral wire grounding 100V/200V
Specified SPD separator Required quantity
Specified SPD separator Short circuit current 100kA or less
Structure
Temperature/humidity
Test standards
Three-phase 4-wire Y connection Neutral point grounding 240V/415V
Three-phase 4-wire Y connection, neutral point grounding 100V/173V
Three-phase three-wire Y connection, neutral point grounding 415V
Three-phase three-wire delta connection one-wire grounding 200V
Voltage protection level Up L-N
Impulse discharge current between N-PE
Nominal discharge current In N-PE
Voltage protection level Up N-PE
Voltage protection level Up L-PE
Part Number
FLT-SEC-T1+T2-2S-350/25-FMProduct
Power supply SPD FLT-SEC seriesHandling Company
Showden Co., Ltd.Categories
Image | Price (excluding tax) | Alarm contact | Applicable wire | Connection terminal | Exam class | Failure display | Follow current breaking rating N-PE | Follow-on current breaking rating between L-N | Impulse discharge current between L-N | Impulse discharge current between N-PE | Maximum continuous working voltage Uc | Nominal discharge current In L-N | Nominal discharge current In N-PE | Protection mode | Recommended wire | Single phase 2 wire neutral point grounding 200V | Single phase 3 wire neutral wire grounding 100V/200V | Specified SPD separator Required quantity | Specified SPD separator Short circuit current 100kA or less | Structure | Temperature/humidity | Test standards | Three-phase three-wire delta connection one-wire grounding 200V | Voltage protection level Up L-N | Voltage protection level Up L-PE | Voltage protection level Up N-PE |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Mechanical | 5.5mm2~22mm2 | Plug-in terminal | Class I/Class II | Normal: Green When faulty: Red | 100A | 25kA | 25kA | 100kA | AC350V | 25kA | 100kA | L-N・N-PE・L-PE | Line side 8mm2 Ground side 14mm2 or more | ●1 unit | ●1 unit | 2 sets | S201312/US221M (with alarm contact) US221 (without alarm contact) | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | ●1 unit | 1.5kV | 2.2kV | 1.5kV |