All Categories
History
Price (excluding tax)
The explosion-proof aluminum cast housing of the PRO6000 is almost the same size as the older models SW6000 and SM6100. This housing is rated to the waterproof standard "NEMA4/4X/IP65", and the display window and dustproof epoxy resin coating are also standardized. Fixing screws are used for installation, and "Flat Base Jig 7084-001" is available as an optional mounting bracket.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Certification
Coating
Housing material
Input Corresponding input value
Input Full Scale Range Internal Accelerometer
Input Full scale range DC4~20mA converter
Input Full scale range External speed sensor
Input Full-scale range External accelerometer
Input Maximum signal amplitude
Input bypass
Input impedance
Input power
Input power consumption
Input power terminal rating
Input reset
Number of input channels
Operating environment Humidity
Operating environment Operating temperature
Operating environment Vibration
Operating environment Waterproof standard
Output DC4~20mA
Output LED display “Alarm” lamp
Output LED display “BYPASS” lamp
Output LED display “OK” lamp
Output buffered converter
Output converter power supply
Output display
Output keypad
Output relay
Weight
Part Number
PRO6000Product
Various vibration switches PROHandling Company
BATROSS Co., Ltd.Image | Price (excluding tax) | Certification | Coating | Housing material | Input Corresponding input value | Input Full Scale Range Internal Accelerometer | Input Full scale range DC4~20mA converter | Input Full scale range External speed sensor | Input Full-scale range External accelerometer | Input Maximum signal amplitude | Input bypass | Input impedance | Input power | Input power consumption | Input power terminal rating | Input reset | Number of input channels | Operating environment Humidity | Operating environment Operating temperature | Operating environment Vibration | Operating environment Waterproof standard | Output DC4~20mA | Output LED display “Alarm” lamp | Output LED display “BYPASS” lamp | Output LED display “OK” lamp | Output buffered converter | Output converter power supply | Output display | Output keypad | Output relay | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | EMC:FCC47CFR, 15-B, classA, ANSIC63.4, CSA:CLASSⅠ, DIV1, (B-D), T4A, CLASSⅡ, DIV1, (E-G), T4A | Epoxy powder coating (blue) | Copper-free aluminum casting | Acceleration, velocity, integrated acceleration, impact force, DC4~20mA | 50~100m/sec^2, 20~76mm/sec | -999.9~+999.9 | 20~127mm/sec | 50~500m/sec^2, 20~117mm/sec | AC5V (p-p): All mV sensor input, DC20mA: All converter input | It is energized by shorting the BYP terminal. Bypass status is maintained as long as the terminals continue to be shorted. Monitoring will resume when the short is removed. | Moving coil speed (configurable): 10kΩ, 100kΩ, constant current sensor: 4mA bias (automatically adjusted to maintain current), DC4~20mA converter: 100Ω | AC85~230V/50~60Hz, DC24V (The input power supply must be specified at the time of ordering, and the power supply specifications cannot be changed after installation.) | 6W or less | Nominal current 17.5A, maximum load current 22A, nominal voltage AC250V, rated voltage AC320V, insulation polyimide, flame retardant (UL94) V0 | Reset retention alarm. Use the alarm reset feature to reset in the field via keypad or display. Remote reset is possible if there is not enough RST terminal temporarily. | 1 | 100% | -40~+70℃ | ≦10G (If the vibration exceeds 10G when measured on-site, install the PRO Switch remotely using an external sensor.) | NEMA4, explosion-proof | Number of outputs: 1, Accuracy: ±1%/full scale, 4mA±0.25mA@minimum, Power supply: DC24V, Short protection circuit included, Dead band current: 3.8mA, Maximum output DC20mA (100%F.S.) | Yellow: In alarm, Red: Shutdown (dual relay only), Off: Not in alarm | Red: SW is in bypass mode, off: SW is in non-bypass mode | Green: Sensor connection OK, Red: Sensor connection NG, Off: SW is not powered on. | Connection terminal: Inside the PRO housing, BNC terminal: Inside the PRO450 housing, Impedance: 1kΩ, Short protection circuit included, Accuracy: ±5% (measured value), 3dB bandwidth: 20kHz, Cable movable: Maximum length 305m | DC24V@25mA (4-20mA-type), DC24V@4mA (rated current & piezo speed), DC12V bias voltage (moving coil speed) | 8 characters x 2 lines, 4 x 7 green dot character display, Resolution: 5 pixels, Displays instantaneous values and their units, You can access the settings menu to change the display and settings, and reset them on the spot. | 4 membrane keypad, ``→'' ``↓'' ``MENU'' ``ENTER'' | 1 unit (2 units optional), SPDT (C type), minimum switching capacity DC100mA@DC5V, maximum capacity AC2,500VA/10A@AV250V, DC5A@DC100V, normally open/closed mutual use | Approximately 1.8kg |