Digital temperature data logger AD-5326TT / AD-5326T-A and Day Co., Ltd.

Price (excluding tax)

$29.25


Model Description

Temperature data from one channel of the temperature data logger's built-in temperature sensor can be recorded. By connecting an external temperature sensor (sold separately), you can record two channels of temperature data: the built-in temperature sensor and the external temperature sensor.


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Accessories

Battery

Data log function Data ID

Data logging function Number of recorded data

Data logging function Recording interval

Data logging function output format

Data output interface

Display items

Display range Temperature CH1 (built-in temperature sensor)

Display range Temperature CH2 (external temperature sensor)

External dimensions

Highest/lowest value memory

Main unit operating environment

Mass

Measurement accuracy Temperature CH1 (built-in temperature sensor)

Measurement accuracy Temperature CH2 (external temperature sensor)

Measurement items

Measurement range Temperature CH1 (built-in temperature sensor)

Measurement range Temperature CH2 (external temperature sensor)

Product code

Sampling interval (measurement interval)

Temperature sensor

Upper limit/lower limit alarm setting range

Waterproof performance

See all 2 models in list
  • Part Number

    AD-5326T

Share this product


500+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Digital temperature data logger AD-5326TT / AD-5326T AD-5326T's performance table

Image Price (excluding tax) Accessories Battery Data log function Data ID Data logging function Number of recorded data Data logging function Recording interval Data logging function output format Data output interface Display items Display range Temperature CH1 (built-in temperature sensor) Display range Temperature CH2 (external temperature sensor) External dimensions Highest/lowest value memory Main unit operating environment Mass Measurement accuracy Temperature CH1 (built-in temperature sensor) Measurement accuracy Temperature CH2 (external temperature sensor) Measurement items Measurement range Temperature CH1 (built-in temperature sensor) Measurement range Temperature CH2 (external temperature sensor) Product code Sampling interval (measurement interval) Temperature sensor Upper limit/lower limit alarm setting range Waterproof performance
Digital temperature data logger AD-5326TT / AD-5326T-Part Number-AD-5326T $ 29.25 Battery (for monitor), USB communication cable, strap, instruction manual ・CR2032 type lithium battery x 2 - Approximately 1 year (with no alarm, recording interval of 1 minute, and ambient temperature of 25°C) 0000~9999 (default value 0001) Maximum 525,600 data (depends on battery life of about 1 year, 525,600 data if recorded for 1 year at a recording interval of 1 minute) 1 minute (00:01) ~12 hours (12:00), can be set in 1 minute intervals (default value 10 minutes) CSV format (TXT format in some browsers) USB2.0 and USB3.0 Temperature CH1 (built-in temperature sensor), temperature CH2 (external temperature sensor), time (Temperature CH2 is when external temperature sensor AX-KO5366 (sold separately) is connected) -20.0~70.0℃ (Resolution 0.1℃) -50.0~99.9℃ (Resolution 0.1℃) *External temperature sensor not included 69 (W) × 45 (H) × 19 (D) mm Memory possible only while recording data Temperature 0.0~60.0℃, humidity 95%RH or less (no condensation) Approx. 45g (including battery) ±1.0℃ (0.0~39.9℃), ±2.0℃ (other measurement ranges) ±1.0℃ (0.0~39.9℃), ±2.0℃ (-20.0~-0.1℃, 40.0~69.9℃), ±3.0℃ (-40.0~-20.1℃, 70.0~90.0℃) *External temperature sensor not included Temperature CH1 (built-in temperature sensor), temperature CH2 (external temperature sensor) (Temperature CH2 is when external temperature sensor AX-KO5366 (sold separately) is connected) 0.0~60.0℃ -40.0~90.0℃ *External temperature sensor not included AD5326T Approximately every 30 seconds Thermistor Temperature CH1: -10.0~60.0℃ (can be set in 0.1℃ increments), Temperature CH2: -40.0~90.0℃ (can be set in 0.1℃ increments) *External temperature sensor not included IP54 (when external temperature sensor and USB communication cable are not connected)

There are 2 models for this product.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Data Loggers Products

Other products of A and Day Co., Ltd.

Reviews shown here are reviews of companies.


View more products of A and Day Co., Ltd.

About Company Handling This Product

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree