Price (excluding tax)
Estimate Required
Model Description
Safety standard
PSE/UL/CUL/CE/CB/FCC/CCC
Note: The stock sales model is a 62368 compatible product.
* The conformity status varies depending on the model number. Please contact us for details.
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Appearance dimensions
L107 X W47 x H30.1 mm | SPU41A-102
L107 X W47 x H30.1 mm | SPU41A-103
L107 X W47 x H30.1 mm | SPU41A-104
L107 X W47 x H30.1 mm | SPU41A-105
L107 X W47 x H30.1 mm | SPU41A-106
L107 X W47 x H30.1 mm | SPU41A-107
L107 X W47 x H30.1 mm | SPU41A-108
L107 X W47 x H30.1 mm | SPU41A-109
L107 X W47 x H30.1 mm
L107 X W47 x H30.1 mm | SPU41A-111
Input voltage
90-264VAC (multi input) | SPU41A-102
90-264VAC (multi input) | SPU41A-103
90-264VAC (multi input) | SPU41A-104
90-264VAC (multi input) | SPU41A-105
90-264VAC (multi input) | SPU41A-106
90-264VAC (multi input) | SPU41A-107
90-264VAC (multi input) | SPU41A-108
90-264VAC (multi input) | SPU41A-109
90-264VAC (multi input)
90-264VAC (multi input) | SPU41A-111
MTBF
100,000 hours (calculated value) | SPU41A-102
100,000 hours (calculated value) | SPU41A-103
100,000 hours (calculated value) | SPU41A-104
100,000 hours (calculated value) | SPU41A-105
100,000 hours (calculated value) | SPU41A-106
100,000 hours (calculated value) | SPU41A-107
100,000 hours (calculated value) | SPU41A-108
100,000 hours (calculated value) | SPU41A-109
100,000 hours (calculated value)
100,000 hours (calculated value) | SPU41A-111
Maximum output
30W | SPU41A-102
30W | SPU41A-103
35W | SPU41A-104
40W | SPU41A-105
40W | SPU41A-106
40W | SPU41A-107
50W | SPU41A-108
50W | SPU41A-109
50W
50W | SPU41A-111
Operating temperature
0 ° C to 70 ° C (due to danger) | SPU41A-102
0 ° C to 70 ° C (due to danger) | SPU41A-103
0 ° C to 70 ° C (due to danger) | SPU41A-104
0 ° C to 70 ° C (due to danger) | SPU41A-105
0 ° C to 70 ° C (due to danger) | SPU41A-106
0 ° C to 70 ° C (due to danger) | SPU41A-107
0 ° C to 70 ° C (due to danger) | SPU41A-108
0 ° C to 70 ° C (due to danger) | SPU41A-109
0 ° C to 70 ° C (due to danger)
0 ° C to 70 ° C (due to danger) | SPU41A-111
Operation humidity
0% to 95% (no water drops) | SPU41A-102
0% to 95% (no water drops) | SPU41A-103
0% to 95% (no water drops) | SPU41A-104
0% to 95% (no water drops) | SPU41A-105
0% to 95% (no water drops) | SPU41A-106
0% to 95% (no water drops) | SPU41A-107
0% to 95% (no water drops) | SPU41A-108
0% to 95% (no water drops) | SPU41A-109
0% to 95% (no water drops)
0% to 95% (no water drops) | SPU41A-111
Output current
5.00A | SPU41A-102
4.61 ~ 3.75 a | SPU41A-103
4.38 ~ 4.18 a | SPU41A-104
3.63 ~ 3.07 a | SPU41A-105
3.07 ~ 2.50 A | SPU41A-106
2.50 ~ 1.90 A | SPU41A-107
2.38 ~ 1.85 A | SPU41A-108
1.85 ~ 1.51 A | SPU41A-109
1.51 ~ 1.25 a
1.25 ~ 1.04 A | SPU41A-111
Output voltage
5 ~ 5.99 VDC | SPU41A-102
6.5 ~ 8 VDC | SPU41A-103
8-11 VDC | SPU41A-104
11 ~ 13 VDC | SPU41A-105
13 ~ 16 VDC | SPU41A-106
16 ~ 21 VDC | SPU41A-107
21 ~ 27 VDC | SPU41A-108
27 ~ 33 VDC | SPU41A-109
33 ~ 40 VDC
40-48 VDC | SPU41A-111
Storage and humidity
0% to 95% (no water drops) | SPU41A-102
0% to 95% (no water drops) | SPU41A-103
0% to 95% (no water drops) | SPU41A-104
0% to 95% (no water drops) | SPU41A-105
0% to 95% (no water drops) | SPU41A-106
0% to 95% (no water drops) | SPU41A-107
0% to 95% (no water drops) | SPU41A-108
0% to 95% (no water drops) | SPU41A-109
0% to 95% (no water drops)
0% to 95% (no water drops) | SPU41A-111
Storage temperature
-40 ° C to 85 ℃ | SPU41A-102
-40 ° C to 85 ℃ | SPU41A-103
-40 ° C to 85 ℃ | SPU41A-104
-40 ° C to 85 ℃ | SPU41A-105
-40 ° C to 85 ℃ | SPU41A-106
-40 ° C to 85 ℃ | SPU41A-107
-40 ° C to 85 ℃ | SPU41A-108
-40 ° C to 85 ℃ | SPU41A-109
-40 ° C to 85 ℃
-40 ° C to 85 ℃ | SPU41A-111
Tr
Five% | SPU41A-102
Five% | SPU41A-103
Five% | SPU41A-104
Five% | SPU41A-105
Five% | SPU41A-106
Five% | SPU41A-107
3% | SPU41A-108
3% | SPU41A-109
2%
2% | SPU41A-111
See all 10 models in list