Price (excluding tax)
Estimate Required
Model Description
Safety standard
PSE, UL, CUL, CB, CE, FCC, GS
ROHS2
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Appearance dimensions
L99.0 x W42.0 x H31.0 mm | SPU21C-102
L99.0 x W42.0 x H31.0 mm | SPU21C-103
L99.0 x W42.0 x H31.0 mm | SPU21C-104
L99.0 x W42.0 x H31.0 mm | SPU21C-105
L99.0 x W42.0 x H31.0 mm | SPU21C-106
L99.0 x W42.0 x H31.0 mm | SPU21C-107
L99.0 x W42.0 x H31.0 mm | SPU21C-108
L99.0 x W42.0 x H31.0 mm | SPU21C-109
L99.0 x W42.0 x H31.0 mm
L99.0 x W42.0 x H31.0 mm | SPU21C-111
Input voltage
90-264vac | SPU21C-102
90-264vac | SPU21C-103
90-264vac | SPU21C-104
90-264vac | SPU21C-105
90-264vac | SPU21C-106
90-264vac | SPU21C-107
90-264vac | SPU21C-108
90-264vac | SPU21C-109
90-264vac
90-264vac | SPU21C-111
MTBF
100,000 hours (calculated value) | SPU21C-102
100,000 hours (calculated value) | SPU21C-103
100,000 hours (calculated value) | SPU21C-104
100,000 hours (calculated value) | SPU21C-105
100,000 hours (calculated value) | SPU21C-106
100,000 hours (calculated value) | SPU21C-107
100,000 hours (calculated value) | SPU21C-108
100,000 hours (calculated value) | SPU21C-109
100,000 hours (calculated value)
100,000 hours (calculated value) | SPU21C-111
Maximum output
15W | SPU21C-102
15W | SPU21C-103
20W | SPU21C-104
20W | SPU21C-105
20W | SPU21C-106
20W | SPU21C-107
20W | SPU21C-108
20W | SPU21C-109
20W
20W | SPU21C-111
Operating temperature
0 to 70 ° C (due to directing) | SPU21C-102
0 to 70 ° C (due to directing) | SPU21C-103
0 to 70 ° C (due to directing) | SPU21C-104
0 to 70 ° C (due to directing) | SPU21C-105
0 to 70 ° C (due to directing) | SPU21C-106
0 to 70 ° C (due to directing) | SPU21C-107
0 to 70 ° C (due to directing) | SPU21C-108
0 to 70 ° C (due to directing) | SPU21C-109
0 to 70 ° C (due to directing)
0 to 70 ° C (due to directing) | SPU21C-111
Operation humidity
0 to 95% (no water drops) | SPU21C-102
0 to 95% (no water drops) | SPU21C-103
0 to 95% (no water drops) | SPU21C-104
0 to 95% (no water drops) | SPU21C-105
0 to 95% (no water drops) | SPU21C-106
0 to 95% (no water drops) | SPU21C-107
0 to 95% (no water drops) | SPU21C-108
0 to 95% (no water drops) | SPU21C-109
0 to 95% (no water drops)
0 to 95% (no water drops) | SPU21C-111
Output current
3.00 ~ 2.50 A | SPU21C-102
2.30 ~ 1.87 A | SPU21C-103
2.50 ~ 1.81 a | SPU21C-104
1.81 ~ 1.53 A | SPU21C-105
1.53 ~ 1.25 a | SPU21C-106
1.25 ~ 0.95 a | SPU21C-107
0.95 ~ 0.74 A | SPU21C-108
0.74 ~ 0.60 A | SPU21C-109
0.60 ~ 0.50 A
0.50 ~ 0.40 A | SPU21C-111
Output voltage
5 ~ 5.99 VDC | SPU21C-102
6.5 ~ 8 VDC | SPU21C-103
8-11 VDC | SPU21C-104
11 ~ 13 VDC | SPU21C-105
13 ~ 16 VDC | SPU21C-106
16 ~ 21 VDC | SPU21C-107
21 ~ 27 VDC | SPU21C-108
27 ~ 33 VDC | SPU21C-109
33 ~ 40 VDC
40-50 VDC | SPU21C-111
Storage and humidity
0 to 95% (no water drops) | SPU21C-102
0 to 95% (no water drops) | SPU21C-103
0 to 95% (no water drops) | SPU21C-104
0 to 95% (no water drops) | SPU21C-105
0 to 95% (no water drops) | SPU21C-106
0 to 95% (no water drops) | SPU21C-107
0 to 95% (no water drops) | SPU21C-108
0 to 95% (no water drops) | SPU21C-109
0 to 95% (no water drops)
0 to 95% (no water drops) | SPU21C-111
Storage temperature
-40-85 ℃ | SPU21C-102
-40-85 ℃ | SPU21C-103
-40-85 ℃ | SPU21C-104
-40-85 ℃ | SPU21C-105
-40-85 ℃ | SPU21C-106
-40-85 ℃ | SPU21C-107
-40-85 ℃ | SPU21C-108
-40-85 ℃ | SPU21C-109
-40-85 ℃
-40-85 ℃ | SPU21C-111
Tr
Five% | SPU21C-102
Five% | SPU21C-103
Five% | SPU21C-104
Five% | SPU21C-105
Four% | SPU21C-106
Four% | SPU21C-107
Four% | SPU21C-108
3% | SPU21C-109
3%
3% | SPU21C-111