Price (excluding tax)
Estimate Required
Model Description
Safety standard
UL, CUL, CB, CE, FCC, PSE
DOE-VI, ROHS2
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Appearance dimensions
L91.0 x W38.0 x H36.0 mm | SPU16B-101
L91.0 x W38.0 x H36.0 mm | SPU16B-102
L91.0 x W38.0 x H36.0 mm | SPU16B-103
L91.0 x W38.0 x H36.0 mm | SPU16B-104
L91.0 x W38.0 x H36.0 mm | SPU16B-105
L91.0 x W38.0 x H36.0 mm | SPU16B-106
L91.0 x W38.0 x H36.0 mm | SPU16B-107
L91.0 x W38.0 x H36.0 mm | SPU16B-108
L91.0 x W38.0 x H36.0 mm | SPU16B-109
L91.0 x W38.0 x H36.0 mm | SPU16B-110
L91.0 x W38.0 x H36.0 mm
Input voltage
90-264vac | SPU16B-101
90-264vac | SPU16B-102
90-264vac | SPU16B-103
90-264vac | SPU16B-104
90-264vac | SPU16B-105
90-264vac | SPU16B-106
90-264vac | SPU16B-107
90-264vac | SPU16B-108
90-264vac | SPU16B-109
90-264vac | SPU16B-110
90-264vac
MTBF
100,000 hours (calculated value) | SPU16B-101
100,000 hours (calculated value) | SPU16B-102
100,000 hours (calculated value) | SPU16B-103
100,000 hours (calculated value) | SPU16B-104
100,000 hours (calculated value) | SPU16B-105
100,000 hours (calculated value) | SPU16B-106
100,000 hours (calculated value) | SPU16B-107
100,000 hours (calculated value) | SPU16B-108
100,000 hours (calculated value) | SPU16B-109
100,000 hours (calculated value) | SPU16B-110
100,000 hours (calculated value)
Maximum output
12W | SPU16B-101
12W | SPU16B-102
12W | SPU16B-103
15W | SPU16B-104
15W | SPU16B-105
15W | SPU16B-106
15W | SPU16B-107
15W | SPU16B-108
15W | SPU16B-109
15W | SPU16B-110
15W
Operating temperature
0 to 70 ° C (due to directing) | SPU16B-101
0 to 70 ° C (due to directing) | SPU16B-102
0 to 70 ° C (due to directing) | SPU16B-103
0 to 70 ° C (due to directing) | SPU16B-104
0 to 70 ° C (due to directing) | SPU16B-105
0 to 70 ° C (due to directing) | SPU16B-106
0 to 70 ° C (due to directing) | SPU16B-107
0 to 70 ° C (due to directing) | SPU16B-108
0 to 70 ° C (due to directing) | SPU16B-109
0 to 70 ° C (due to directing) | SPU16B-110
0 to 70 ° C (due to directing)
Operation humidity
0 to 95% (no water drops) | SPU16B-101
0 to 95% (no water drops) | SPU16B-102
0 to 95% (no water drops) | SPU16B-103
0 to 95% (no water drops) | SPU16B-104
0 to 95% (no water drops) | SPU16B-105
0 to 95% (no water drops) | SPU16B-106
0 to 95% (no water drops) | SPU16B-107
0 to 95% (no water drops) | SPU16B-108
0 to 95% (no water drops) | SPU16B-109
0 to 95% (no water drops) | SPU16B-110
0 to 95% (no water drops)
Output current
2.5A MAX | SPU16B-101
2.50 ~ 2.00A | SPU16B-102
1.84 ~ 1.50A | SPU16B-103
1.87 ~ 1.36A | SPU16B-104
1.36 ~ 1.15A | SPU16B-105
1.15 ~ 0.94A | SPU16B-106
0.94 ~ 0.72A | SPU16B-107
0.72 ~ 0.55A | SPU16B-108
0.55 ~ 0.45a | SPU16B-109
0.45 ~ 0.37A | SPU16B-110
0.37 ~ 0.31a
Output voltage
3 ~ 5VDC | SPU16B-101
5 ~ 5.99VDC | SPU16B-102
6.5 ~ 8VDC | SPU16B-103
8-11VDC | SPU16B-104
11 ~ 13VDC | SPU16B-105
13 ~ 16VDC | SPU16B-106
16 ~ 21VDC | SPU16B-107
21 ~ 27VDC | SPU16B-108
27 ~ 33VDC | SPU16B-109
33 ~ 40VDC | SPU16B-110
40-48VDC
Storage and humidity
0 to 95% (no water drops) | SPU16B-101
0 to 95% (no water drops) | SPU16B-102
0 to 95% (no water drops) | SPU16B-103
0 to 95% (no water drops) | SPU16B-104
0 to 95% (no water drops) | SPU16B-105
0 to 95% (no water drops) | SPU16B-106
0 to 95% (no water drops) | SPU16B-107
0 to 95% (no water drops) | SPU16B-108
0 to 95% (no water drops) | SPU16B-109
0 to 95% (no water drops) | SPU16B-110
0 to 95% (no water drops)
Storage temperature
-40-85 ℃ | SPU16B-101
-40-85 ℃ | SPU16B-102
-40-85 ℃ | SPU16B-103
-40-85 ℃ | SPU16B-104
-40-85 ℃ | SPU16B-105
-40-85 ℃ | SPU16B-106
-40-85 ℃ | SPU16B-107
-40-85 ℃ | SPU16B-108
-40-85 ℃ | SPU16B-109
-40-85 ℃ | SPU16B-110
-40-85 ℃
Tr
7% | SPU16B-101
Five% | SPU16B-102
Five% | SPU16B-103
Five% | SPU16B-104
Five% | SPU16B-105
Five% | SPU16B-106
Five% | SPU16B-107
Five% | SPU16B-108
Five% | SPU16B-109
3% | SPU16B-110
3%
See all 11 models in list