Infrared sensor (non-contact) RD-600 series-RD-622-LM
Infrared sensor (non-contact) RD-600 series-Shinko Technos Co., Ltd.

Infrared sensor (non-contact) RD-600 series
Shinko Technos Co., Ltd.


About This Product

■ Measurement of glossy metal surface is possible Small infrared temperature sensor of 2.3 meters wavelength. Glossy metal surface, secondary metal processing, and ceramic materials can be measured ■ Measurement through the glass is possible It is possible to measure through general glass and pass heat -resistant glass ■ Ultra -small sensor head Ultra -small sensor head with a diameter of 14 mm and 28 mm long, can be used anywhere ■ Viper temperature can be used up to 85 ° C Can be used up to 85 ° C for the surrounding temperature without cooling ■ Measurement of metal surface from 50 ° C can be measured Measurement of metal surface from low temperature from 50 ° C ■ Measurement of low radioactivity objects is possible Low radioactivity objects, which were previously difficult to measure due to the short wavelength of 2.3 μm, can be measured.

  • Product

    Infrared sensor (non-contact) RD-600 series




*Please note that we may not be able to accommodate sample requests.

2 Models of Infrared sensor (non-contact) RD-600 series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm output Ambient temperature Analog output DC current Analog output DC voltage Analog output thermocouple Backlight display color switching Cable diameter Compatible safety standard Drip -proof / dustproof structure Emissivity Error message External dimensions Material Measurement wavelength Mounting method Peripheral humidity Permeability Power-supply voltage Reproduction (*1) Response time Signal processing System accuracy (*1) Temperature coefficient (*3) Temperature decomposition ability Temperature range Viewing angle Warm -up display cable length display storage temperature
Infrared sensor (non-contact) RD-600 series-Part Number-RD-622-LM

RD-622-LM

Available upon quote ・ Maximum warning
・ Open collector output
・ Capacity: 24V DC, up to 50mA
・ Sensor: -20 ~ 85 ℃
・ Amplifier part: 0 to 65 ° C
0 ~ 20 ma DC, 4 ~ 20 ma DC, load resistance 500Ω or less 0 ~ 5 V DC, 0 ~ 10 V DC, load resistance 100 kΩ or more K, J, Output impedance 20Ω Normal: Green, lower limit warning output: blue, maximum warning output: Red (open collector output ON), lower limit warning output and upper limit warning output: purple (open collector output ON) φ2.8mm CE marking IP65 0.100 ~ 1.100 If there is a problem, display an error message. (Backlight: green) ・ Sensor part: 31 × φ14 mm, M12 × 1
・ Amplifier part: 89 x 70 x 30 mm (horizontal x vertical x depth)
・ Sensor: Stainless
・ Amplifier part: Zinc diecast
2.3 μm ・ Sensor unit: Mounting bracket fixing method (Using mounting brackets for separately sold)
・ Amplifier part: Installation by screws
10 ~ 95%RH (but not condensation) 0.100 ~ 1.100 8 ~ 36 V DC, up to 100 MA ± (0.1 % of reading + 1 ℃) (*2) (*1): A surrounding temperature of 23 ± 5 ° C (*2): ε = 1/response time 1 second 1 MS (90 %response) (*4) (*4): Dynamic adaptation at the low -traffic light level Average, peak hold, bottom hold ± (0.3% of Reading+2 ℃) However, thermal electronics output accuracy: ± 2.5 ° C or 1% of Reading (*1): A peripheral temperature of 23 ± 5 ° C. Either of ± 0.05 ° C/℃ or ± 0.05 %/℃ (*3): Rip -off temperature (sensor head) If it is lower than 18 ° C and higher than 28 ° C 0.1 ° C (*2) (*2): ε = 1/response time 1 second 50 ~ 400 ° C (*)

(*): Measurement target temperature> sensor head temperature + 25 ℃
22: 1 After the power is turned on, [.i.n.i.t] is displayed on the display for several seconds. After that, the temperature to be measured is displayed in the display. The backlight of the display changes depending on the alarm condition. 3m LCD
·5-digit
・ Backlight normal: green
・ At the lower limit warning output: Blue
・ Uptery warning output: Red
・ Lower warning output and upper limit warning output: purple
・ Sensor: -40 to 85 ℃
・ Amplifier part: -40 to 85 ℃
Infrared sensor (non-contact) RD-600 series-Part Number-RD-675-HM

RD-675-HM

Available upon quote ・ Maximum warning
・ Open collector output
・ Capacity: 24V DC, up to 50mA
・ Sensor: -20 ~ 85 ℃
・ Amplifier part: 0 to 65 ° C
0 ~ 20 ma DC, 4 ~ 20 ma DC, load resistance 500Ω or less 0 ~ 5 V DC, 0 ~ 10 V DC, load resistance 100 kΩ or more K, J, Output impedance 20Ω Normal: Green, lower limit warning output: blue, maximum warning output: Red (open collector output ON), lower limit warning output and upper limit warning output: purple (open collector output ON) φ2.8mm CE marking IP65 0.100 ~ 1.100 If there is a problem, display an error message. (Backlight: green) ・ Sensor part: 31 × φ14 mm, M12 × 1
・ Amplifier part: 89 x 70 x 30 mm (horizontal x vertical x depth)
・ Sensor: Stainless
・ Amplifier part: Zinc diecast
2.3 μm ・ Sensor unit: Mounting bracket fixing method (Using mounting brackets for separately sold)
・ Amplifier part: Installation by screws
10 ~ 95%RH (but not condensation) 0.100 ~ 1.100 8 ~ 36 V DC, up to 100 MA ± (0.1 % of reading + 1 ℃) (*2) (*1): A surrounding temperature of 23 ± 5 ° C (*2): ε = 1/response time 1 second 1 MS (90 %response) (*4) (*4): Dynamic adaptation at the low -traffic light level Average, peak hold, bottom hold ± (0.3% of Reading+2 ℃) However, thermal electronics output accuracy: ± 2.5 ° C or 1% of Reading (*1): A peripheral temperature of 23 ± 5 ° C. Either of ± 0.05 ° C/℃ or ± 0.05 %/℃ (*3): Rip -off temperature (sensor head) If it is lower than 18 ° C and higher than 28 ° C 0.1 ° C (*2) (*2): ε = 1/response time 1 second 150-1000 ° C (*) (*): Measurement target temperature> Sensor head temperature + 25 ℃ 75: 1 After the power is turned on, [.i.n.i.t] is displayed on the display for several seconds. After that, the temperature to be measured is displayed in the display. The backlight of the display changes depending on the alarm condition. 3m LCD
·5-digit
・ Backlight normal: green
・ At the lower limit warning output: Blue
・ Uptery warning output: Red
・ Lower warning output and upper limit warning output: purple
・ Sensor: -40 to 85 ℃
・ Amplifier part: -40 to 85 ℃

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees