Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E-CCS53E
Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E-Endress+Hauser Group Services AG

Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E
Endress+Hauser Group Services AG


About This Product

■Application Total chlorine is a good indicator of residual disinfectant in wastewater/process water because it is a mixture of free and combined chlorine. Memosens CCS53E can perform continuous measurements of total chlorine even after periods of no chlorine present. This allows for "zero" chlorine (no chlorine) measurements. Thanks to Memosens 2.0 technology, this sensor combines maximum process and data integrity with simple operability. This is the perfect basis for predictive maintenance. The Memosens CCS53E total chlorine sensor provides reliable measurements in applications such as: ・Wastewater treatment facility: Realizes wastewater reuse by managing water quality at drainage outlets ・Process water in utilities in all industries: Detecting chlorine to prevent damage to cooling towers, etc. Food and beverage industry: ensuring high food quality in hygienic filling and washing water and protecting membranes in reverse osmosis systems ・Drinking water: Guarantees sterilization and prevents excessive addition of chemicals ・Pool water: Detection of pollutants ■Advantages ・This sensor can take measurements immediately without stopping operation even after a period in which chlorine is not present. This continuous measurement allows you to react quickly to process changes and ensures regulatory compliance. - Easy-to-maintain diaphragm sensor reduces maintenance costs at measurement points when compared to color measurement systems Increased process uptime: Plug-and-play replacement of pre-calibrated sensors allows for quick sensor replacement. Additionally, Memosens 2.0 also reduces polarization time. - Easily connects to Liquiline multi-parameter transmitters, allowing for easy combination with other relevant water analysis parameters such as pH and ORP. ・Wide measurement range for various applications: Total chlorine measurement from zero measurement and trace measurement to a maximum of 20 mg/l is possible.

  • Product

    Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E

Share this product


60+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E

Product Image Part Number Price (excluding tax) Application Characteristics Connection External dimensions Material Measurement method Measurement principle Measuring range Process pressure Process temperature Structure Temperature sensor
Memosens Disinfection Sensor for Wastewater Treatment and Utilities in All Industries Digital Total Chlorine Sensor Memosens CCS53E-Part Number-CCS53E

CCS53E

Available upon quote Monitoring and control of sterilization treatment at wastewater outlet of wastewater treatment plant, reuse of discharged water
Utilities for all industries
Sterilization adjustment of drinking water
All sterilization measurement points
Swimming pools with efficient disinfectant dosing
Diaphragm measurement of total chlorine Electromagnetic, digital connection head with Memosens2.0 technology Caliber: 25 mm (0.98 in)
Length: 161 mm (6.34 in)
Sensor shaft: POM
Diaphragm: PET/PVDF
Diaphragm cap: PVDF
Total chlorine consisting of free chlorine (HOCl, OCl-) and combined chlorine (chloramines)
All components are reduced at the working electrode
Almost unaffected by pH
Total chlorine 0~5 mg/l total chlorine or
0~20 mg/l total chlorine
100 kPa gage pressure (14.5 psi gage pressure)
up to 200 kPa (up to 29 psi)
0~55℃, no freezing
(32~130°F)
PET diaphragm type 2-electrode measurement cell Equipped with 10k NTC (Memosens)

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree