Product
Special water for water purification (water purification, water, water supply) GR-10-35/27A/30A monitorHandling Company
IWAKI CO., LTD.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Contact capacity | Contact signal | Installation method | Linearness | Measurement ingredient | Measurement method | Measurement principle | Measurement range | Quotal lower limit value | Radius | Repetition | Response time | Spand lift | Transmission output | Water inspection PH range | Zero drift | display | memory card | power consumption | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GR-10 (-35/30A) |
Available upon quote | AC250V 1a Max. | Maximum, lower limit, control output, device abnormality: 1A each | Attach walls or 50A pipes (optional) | ± 5% of full scale (standard) (pH, temperature, constant power conduction) | Water purification / water / water supply residue chlorine | Bead cleaning type microscope 3 electrode system | Polaralograph method |
0.00 ~ 3.00 mg/L (GR-10-35), 0.00 ~ 2.00 mg/L (GR-10-27A/30A) Other measurements are factory shipping options. |
0.05mg/L or less (fluctuation coefficient 10%) | 5ms/m or higher (however, chloride ions 1,000 mg/l or less) | Within ± 2%+1 digit of full scale (standard) (pH, temperature, constant electric leader) | Within about 1 minute (90%response) | Within ± 10% / month of full scale (standard) | DC4 ~ 20ma Insulated maximum load resistance 550Ω | PH5.8 ~ 8.6 (within 0.5 pH) | Under ± 1%+1 digit of full scale (standard) / month |
Capacity display part (PV) Digital 4 -digit LED display (red) Minimal resolution: 0.01 mg/L Configuration value display part (SV) Digital 4 -digit LED display (green) |
Save SDHC/SD card log data storage | 20VA | 1φac100V ~ 240V ± 10% 50/60Hz | |
GR-10 (-27A-1) |
Available upon quote | AC250V 1a Max. | Maximum, lower limit, control output, device abnormality: 1A each | Attach walls or 50A pipes (optional) | - | Water purification / water / water supply residue chlorine | Bead cleaning type microscope 3 electrode system | Polaralograph method |
0.00 ~ 3.00 mg/L (GR-10-35), 0.00 ~ 2.00 mg/L (GR-10-27A/30A) Other measurements are factory shipping options. |
0.05mg/L or less (fluctuation coefficient 10%) | 5ms/m or higher (however, chloride ions 1,000 mg/l or less) | Within ± 5%+1 digit of full scale (standard) (pH, temperature, constant electric leader) | Within about 1 minute (90%response) | - | DC4 ~ 20ma Insulated maximum load resistance 550Ω | PH5.8 ~ 8.6 (within 0.5 pH) | - |
Capacity display part (PV) Digital 4 -digit LED display (red) Minimal resolution: 0.01 mg/L Configuration value display part (SV) Digital 4 -digit LED display (green) |
Save SDHC/SD card log data storage | 20VA | 1φac100V ~ 240V ± 10% 50/60Hz | |
GR-10 (-27A-2) |
Available upon quote | AC250V 1a Max. | Maximum, lower limit, control output, device abnormality: 1A each | Attach walls or 50A pipes (optional) | - | Water purification / water / water supply residue chlorine | Bead cleaning type microscope 3 electrode system | Polaralograph method |
0.00 ~ 3.00 mg/L (GR-10-35), 0.00 ~ 2.00 mg/L (GR-10-27A/30A) Other measurements are factory shipping options. |
0.05mg/L or less (fluctuation coefficient 10%) | 5ms/m or higher (however, chloride ions 1,000 mg/l or less) | Within ± 5%+1 digit of full scale (standard) (pH, temperature, constant electric leader) | Within about 1 minute (90%response) | - | DC4 ~ 20ma Insulated maximum load resistance 550Ω | PH5.8 ~ 8.6 (within 0.5 pH) | - |
Capacity display part (PV) Digital 4 -digit LED display (red) Minimal resolution: 0.01 mg/L Configuration value display part (SV) Digital 4 -digit LED display (green) |
Save SDHC/SD card log data storage | 20VA | 1φac100V ~ 240V ± 10% 50/60Hz | |
GR-10 (-27A-3) |
Available upon quote | AC250V 1a Max. | Maximum, lower limit, control output, device abnormality: 1A each | Attach walls or 50A pipes (optional) | - | Water purification / water / water supply residue chlorine | Bead cleaning type microscope 3 electrode system | Polaralograph method |
0.00 ~ 3.00 mg/L (GR-10-35), 0.00 ~ 2.00 mg/L (GR-10-27A/30A) Other measurements are factory shipping options. |
0.05mg/L or less (fluctuation coefficient 10%) | 5ms/m or higher (however, chloride ions 1,000 mg/l or less) | Within ± 5%+1 digit of full scale (standard) (pH, temperature, constant electric leader) | Within about 1 minute (90%response) | - | DC4 ~ 20ma Insulated maximum load resistance 550Ω | PH5.8 ~ 8.6 (within 0.5 pH) | - |
Capacity display part (PV) Digital 4 -digit LED display (red) Minimal resolution: 0.01 mg/L Configuration value display part (SV) Digital 4 -digit LED display (green) |
Save SDHC/SD card log data storage | 20VA | 1φac100V ~ 240V ± 10% 50/60Hz |
Click on the part number for more information about each product