Primary dissolving molecular molecular agent Automatic dissolution device PDE series-PDE-250
Primary dissolving molecular molecular agent Automatic dissolution device PDE series-IWAKI CO., LTD.

Primary dissolving molecular molecular agent Automatic dissolution device PDE series
IWAKI CO., LTD.


About This Product

■ Patent salary mechanism without movable parts Parking to the molten tank is long life without a movable part because it is performed by the pulse air blowing from the slit part in the feeder. You can reduce maintenance costs and man -hours. Pulse air also has the effect of preventing the slits from blocking. ■ Prevents undiluted with primary dissolution (Pat.pend.) Inside the water supply line, the water particle and powdered particles are quickly mixed with the primary dissolution mechanism that is directly poured into a fan -shaped water line, and supplies a high -quality solution that has not been dissolved. I can. ■ Shut out moisture in the hopper feeder The air supplied to the chamber room in the hopper and the feeder is dehumidified by a hollow -film type dry air unit. You can always keep the molecular coach powder in the device in a dry state. (When the pounding operation is suspended) ■ Easy installation ・ Easy operation Operation is extremely easy. After connecting the power supply / water supply line and compressed air line, a polymer agent powder is put into the hopper. After that, simply adjust and set the amount of flour and switch the operation mode to "automatic". ■ Lightweight / compact design Since the volume is 1/3 to 1/5 compared to the conventional manual melting device, it can be installed in a narrow space.

  • Product

    Primary dissolving molecular molecular agent Automatic dissolution device PDE series




*Please note that we may not be able to accommodate sample requests.

3 Models of Primary dissolving molecular molecular agent Automatic dissolution device PDE series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Compressed air specifications Feeder supply ability Feeder system Hopper capacity (attached capacity) Reference supply concentration 0.1WT % Solving tank capacity (made of PVC) Water supply specifications option power supply
Primary dissolving molecular molecular agent Automatic dissolution device PDE series-Part Number-PDE-250

PDE-250

Available upon quote Air volume: 80L/min or higher air pressure: 0.3 ~ 0.85MPa
* Compressed air must not contain liquid water (such as water drops) or foreign substances.
5-100g/min Pulse air payment method 3L (~ 10L) 95L/hr
* The above values ​​are the reference value when the dissolution time is 2 hours. The melting time varies depending on the type of coarse powder and water temperature.
Nominal 250L, valid 195L Water supply: 30L/min or higher water supply pressure: 0.15 ~ 0.9 8MPa
* The water must not be mixed in the water.
Hopper lower limit level sensor, compressor,
Compressor drive circuit, dissolved liquid transfer pump, floors switch
AC200V 50/60Hz Three Phase

PDE-500

Available upon quote Air volume: 80L/min or higher air pressure: 0.3 ~ 0.85MPa
* Compressed air must not contain liquid water (such as water drops) or foreign substances.
5-100g/min Pulse air payment method 10L (~ 30L) 95L/hr
* The above values ​​are the reference value when the dissolution time is 2 hours. The melting time varies depending on the type of coarse powder and water temperature.
Nominal 500L, valid 395L Water supply: 30L/min or higher water supply pressure: 0.15 ~ 0.9 8MPa
* The water must not be mixed in the water.
Hopper lower limit level sensor, compressor,
Compressor drive circuit, dissolved liquid transfer pump, floors switch
AC200V 50/60Hz Three Phase

PDE-1000

Available upon quote Air volume: 80L/min or higher air pressure: 0.3 ~ 0.85MPa
* Compressed air must not contain liquid water (such as water drops) or foreign substances.
5-100g/min Pulse air payment method 20L (~ 50L) 95L/hr
* The above values ​​are the reference value when the dissolution time is 2 hours. The melting time varies depending on the type of coarse powder and water temperature.
Nominal 1000L, valid 850L Water supply: 30L/min or higher water supply pressure: 0.15 ~ 0.9 8MPa
* The water must not be mixed in the water.
Hopper lower limit level sensor, compressor,
Compressor drive circuit, dissolved liquid transfer pump, floors switch
AC200V 50/60Hz Three Phase

Click on the part number for more information about each product

Other products of IWAKI CO., LTD.


View more products of IWAKI CO., LTD.

About Company Handling This Product

IWAKI CO., LTD.

  • Japan
  • Since 1956
  • 994 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.