Product
HACCP compatible high-functional residual chlorine concentration meter GRF-30-27A/40/45/43ht/45HT monitorHandling Company
IWAKI CO., LTD.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Contact signal | Control output method | Effective measurement range | External signal input | Installation method | Measurement ingredient | Measurement method | Measurement principle | Minimal resolution | Repetition | Response time | Transmission output | Verable measurement lower limit | Water inspection PH range | display | memory card | power consumption | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GRF-30 RE-21 |
Available upon quote |
Capacity control output relay AC / DC double semiconductor relay AC Peak 400V 0.5A Max. Other relay mechanical relay AC250V 1A Max. |
ON/OFF control method or proportional control method | 5.0 ~ 50.0mg/L (standard) | DC4 ~ 20ma input resistance 100Ω (PH signal, etc.) | Wall installation or 50A pole installation (optional) | Effective chlorine | Bead cleaning / electrolytic cleaning combined type micro solid 3 electrode type | Electrochemical measurement method | 0.1mg/L | Within ± 5%+1 digit of full scale (standard) (flow rate, pH, temperature, constant power conduction) | Within 1 minute (90%response) | DC4 ~ 20ma Insulated maximum load resistance 550Ω | 1/10 full scale | PH5.8 ~ 10.5 (within a floating width of 1pH) |
Measurement value display part (PV): Digital 4 -digit LED display (red) External input display (SV): Digital 4 -digit LED display (green) |
SDHC/SD card log data storage (standard size SD slot) | Approximately 10va | 1φac100 ~ 240V ± 10% 50/60Hz | |
GRF-30 RE-30 |
Available upon quote |
Capacity control output relay AC / DC double semiconductor relay AC Peak 400V 0.5A Max. Other relay mechanical relay AC250V 1A Max. |
ON/OFF control method or proportional control method | 30 ~ 300mg/L (standard) | DC4 ~ 20ma input resistance 100Ω (PH signal, etc.) | Wall installation or 50A pole installation (optional) | Effective chlorine | Bead cleaning / electrolytic cleaning combined type micro solid 3 electrode type | Electrochemical measurement method | 1mg/l | Within ± 5%+1 digit of full scale (standard) (flow rate, pH, temperature, constant power conduction) | Within 1 minute (90%response) | DC4 ~ 20ma Insulated maximum load resistance 550Ω | 1/10 full scale | PH5.8 ~ 10.5 (within a floating width of 1pH) |
Measurement value display part (PV): Digital 4 -digit LED display (red) External input display (SV): Digital 4 -digit LED display (green) |
SDHC/SD card log data storage (standard size SD slot) | Approximately 10va | 1φac100 ~ 240V ± 10% 50/60Hz |
Click on the part number for more information about each product