Cerabar PMP51B that measures liquids, gas, steam, and liquid levels and output analog or digital signalsHandling Company
Endress+Hauser Group Services AGProduct Image | Part Number | Price (excluding tax) | Ambient temperature | Characteristic | Class certification | Design certification | Drinking water authentication | Features | Gasket material | Housing material | Inclusion solution | Long -term stability | Maximum overpressure limit | Maximum turndown | Measurement principle | Measuring cell | Minimum calibration span | Process connection | Process menblene material | Process temperature | Safety certification | Sanitari process connection | Sanitation standard conformity certificate | Standard accuracy | Standard conformity certificate/authentication | Supply voltage | Vacuum resistance | communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CERABAR PMP51B |
Available upon quote |
-40 ~+85 ° C C (-40 ~+185 ° f) |
Pressure transmission device equipped with a metal menblene for high -precision measurement of liquid or gas Select with a diaphragm seal. Settings using intuitive and easy -to -understand wizards |
Class certification |
EN10204-3.1, Nace MR0175, NACE MR0103 |
NSF |
Operation and maintenance with Bluetooth® and Smartblue apps, Easy identification by RFID tag, Plug and play function |
Ptfe | aluminum |
Silicon oil, inert oil, Plant oil, High temperature/low temperature oil |
0.1 %/year of URL 0.2 %/5 years of URL 0.25 %/10 years of URL |
280 mpa (40,600 PSI) | 100: 1 | Absolute pressure and gauge pressure |
40 kpa ~ 40 mpa (6 ~ 6,000 PSI) |
2 KPA (0.3 PSI) |
screw: G1/2 ~ G2, R1/2, MNPT3/4 ~ MNPT2, Fnpt1/2, Flange: DN25 ~ DN80, NPS 1 ~ 3 " |
Equivalent to SUS316L, Aloy C, Tantal, Monel, Ptfe |
standard: -40 ~+125 ° C C (-40 ~+257 ° f) Diafram Seal: -40 ~+400 ° C (-40 ~+752 ° f) |
SIL | Sanitari process connection | Sanitation standard conformity certificate |
standard: Up to 0.075 % High -precision school correction: Up to 0.055 % |
ATEX, IEC EX, CSA C/US, NEPSI |
Ex D, EX E, non -explosions: DC 10.5 ~ 35 V EX I: DC 10.5 ~ 30 V |
5 KPA (0.725 PSI) |
4 ~ 20 ma, 4 ~ 20 ma heat |
Endress+Hauser Group Services AG