Cerabar PMC21, which measures liquids, gas, steam, and liquid levels and output analog or digital signalsHandling Company
Endress+Hauser Group Services AGProduct Image | Part Number | Price (excluding tax) | Ambient temperature | Characteristic | Class certification | Design certification | Long -term stability | Maximum overpressure limit | Measurement principle | Measuring cell | Process connection | Process temperature | Standard accuracy | Standard conformity certificate/authentication | Supply voltage | communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CERABAR PMC21 |
Available upon quote |
-40 ~+85 ° C C (-40 ~+185 ° f) |
Cost -efficient pressure converter, ceramic measurement diaphragm with diaflum, capacitance type sensor | RINA, KR |
EN 10204-3.1 Final inspection report Prohibition of oil Cleaning process for oxygen applications |
URL/0.2% of the year |
Up to 6 mpa (900 PSI) |
Absolute pressure and gauge pressure |
+10 kpa ~+4 mpa (+1.5 ~+600 PSI) |
screw: G1/4, G1/2, MNPT 1/4, MNPT 1/2, Din13, JIS R1/2 |
-25 ~+100 ° C (-13 ~+185 ° f) |
0.3 % | ATEX, FM, CSA, IEC EX, NEPSI, EAC | DC 10 ... 30 V | 4 ... 20 ma |
Endress+Hauser Group Services AG