Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters-Memosens CLS16E
Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters-Endress+Hauser Group Services AG

Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters
Endress+Hauser Group Services AG

🍎 Food Industry Use 💊 Pharmaceutical & Medical Use 🧬 Bio Industry Use

About This Product

Memosens 2.0, an electrode -type 2.0, ideal for life science and food industry Sanitar application ◾️ Application Memosens CLS16E is a top -level conductive sensor that uses a FDA and USP class VI certification acquisition. High measurement accuracy provides highly reliable data and optimizes processes and products. Because the sensor silver can be exchanged, it achieves a robust and long operating life. With Memosens 2.0 technology, CLS16E can save more proofreading and process data, facilitate predictive maintenance, and provide a foundation for IIOT services. Memosens CLS16E enables process monitor and control by measuring conductivity in the following applications using pure water and ultra -pure water. ・ Injecting water (WFI) ・ Electrical removal ion ・ Ion exchange ・ Reverse penetration membrane ·distillation This digital sensor that acquire international explosion -proof authentication such as ATEX, FM, CSA, NEPSI, etc. is suitable for use in dangerous places. ◾️Anucial -MEHEDG, USP class VI, ASME, and FDA -compliant Memosens CLS16E acquired quality certificate and EN 10204 3.1 Material certificate is ideal for life science and food industry's sanitar application. -The sensor is possible to sterilize and auto crave, and supports CIP (constant cleaning) and SIP (sterilized sterilization). ・ Because it is made of stainless steel, it is robust, corrosion resistance, and realizes a longer operation life by replaced stickers. ・ It maintains high measurement accuracy even under high temperature/high pressure, provides highly reliable data, and optimizes the quality of processes and products. ・ Non -contact type electromagnetic induction signal transmission ensures high process consistency. ・ Compatible with IIOT: Memosens 2.0 records proofreading and process data with more information, enables excellent trend identification, provides the basics of advanced IIOT services that have been preserved and enhanced.

  • Product

    Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters
  • Usage Scenarios

    Food Industry Use / Pharmaceutical & Medical Use / Bio Industry Use

Share this product


270+ people viewing

Last viewed: 19 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters

Product Image Part Number Price (excluding tax) Additional certification Characteristic Explosion -proof standard conformity certificate External dimensions Material Measurement principle Measurement range Process pressure Process temperature Protection grade Temperature sensor application connection structure
Water quality analysis meter Digital conductor ratio MEMOSENS CLS16E corresponding to water quality analysis parameters-Part Number-Memosens CLS16E

Memosens CLS16E

Available upon quote Material certificate 3.1
EHEDG compatible, Sanitari design
COC ASME BPE
Compatible with CGMP requirements
Two -electrode conductor sensor of Sanitari specification ATEX, NEPSI, CSA, IECEX, InMetro, EAC EX Electronic diameter: 17 mm (0.66 INCH)
Electrode: 54 mm (2.13 INCH)
Insulation: PEEK
Electrode: Polished stainless steel 1.4435
Seal: ISOLAST (FFKM) FDA conformity
Electrode K = 0.1: 0.04 ~ 500 µs/cm 1.3 mpa (188 PSI), 20 ° C (68 ° f)
0.9 mpa (130 PSI), 120 ° C (248 ° f)
-5 ~ 120 ° C (23 ~ 248 ° f)
Sterinium: Up to 150 ° C (at 500 kpa)
(Up to 302 ° F (73 PSI))
IP68 PT1000 Pure water and super pure water
Pharmaceutical industry
Final rinse process
Wfi
Process Connection: Varivent, Neumo, Biocontrol, Clamp
Sensor connection: Memosens 2.0 Digital connection head with electromagnetic induction transmission equipped with technology
Saniterary specification with electrode 2 electrode type conductive sensor, electrolytic polished.

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree