Compatible with various samples single sample changer Xsample 330-XSAMPLE 330
Compatible with various samples single sample changer Xsample 330-Anton Paar GmbH

Compatible with various samples single sample changer Xsample 330
Anton Paar GmbH


About This Product

■ A single sample changer for various samples ・ In addition to the new peristalic pump of the industrial grade, the XSAMPLE 330, which is equipped with an automatic cleaning function, is the best unit for continuous measurement of various low viscosity samples with completely different characteristics. ・ When the measurement is completed, the sample is emitted or recovered, and the system is automatically cleaned with up to two types of cleaning solution. The drying is operated by the operator. The following sample measurement cells can be perfectly prepared. ■ Automatic cleaning ・ Automatic cleaning and drying every time a sample measurement -perfect measurement preparation ・ Each cleaning procedure can use up to two types of cleaning agents ・ Set the cleaning procedure in detail and improve the efficiency of measurement work ■ Compatible with various samples ・ By filling with a recipient pump, it supports a wide range of sample viscosity up to 3.000 mpa.s.S. ・ All of the durable materials are durable so that corrosive samples (phosphoric acid, trichlorolac acid, etc.) can be handled. ・ Perfect measurement result by filling mode that can be adjusted according to the type of sample ■ Handling of efficient samples, simple operation ・ Measurement with minimum samples according to the scale of the system ・ Easy operation with a user interface built into the master device ・ Measurement in the same procedure regardless of the viscosity of the sample -Stop filling operation by sensor control ・ Automatic sample collection device -Collected expensive samples, dangerous samples into vials ■ Compatible device ・ DMA ・ Lovis2000 m/me

  • Product

    Compatible with various samples single sample changer Xsample 330




*Please note that we may not be able to accommodate sample requests.

2 Models of Compatible with various samples single sample changer Xsample 330

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Altitude Compressed air supply or nitrogen gas Environmental conditions (en 61,010) Excluding dimensions master devices (length x width x height) Filling mode Minimum sample amount Operating temperature Overvoltage category Pollution Power supply part Product No Required air quality Standard time required for filling/measuring cycles Viscosity range Weight (excluding master devices)
Compatible with various samples single sample changer Xsample 330-Part Number-XSAMPLE 330

XSAMPLE 330

Available upon quote Up to 3,000 m Up to 2 BAR (relative pressure) Limited use of indoor use 205 mm x 148 mm x 185 mm One -way suction mode, one -way suction and reverse suction Approximately 10 ~ 20 ml 15 ~+35 ℃ II 2 Supplies from the master device, the AC power supply voltage is the technical specification nameplate on the back of the master device (protection earth required) 184370 ISO 8,573-1 Class 3 compliant: Maximum particle size: 5 μm, maximum pressure dew point: -20 ° C, maximum oil content: 1 mg/m³ 2-5 minutes Up to 3,000 mpa • S in the peripheral temperature and measurement temperature (if the viscosity of the sample exceeds 500 mpa • s at the peripheral temperature and measurement temperature, bubbles may occur at the time of filling.) Approximately 3.7 kg
Compatible with various samples single sample changer Xsample 330-Part Number-Xsample 330 (High-Resistance)

Xsample 330 (High-Resistance)

Available upon quote Up to 3,000 m Up to 2 BAR (relative pressure) Limited use of indoor use 205 mm x 148 mm x 205 mm One -way suction mode, one -way suction and reverse suction Approximately 10 ~ 20 ml 15 ~+35 ℃ II 2 Supplies from the master device, the AC power supply voltage is the technical specification nameplate on the back of the master device (protection earth required) 184370 ISO 8,573-1 Class 3 compliant: Maximum particle size: 5 μm, maximum pressure dew point: -20 ° C, maximum oil content: 1 mg/m³ 2-5 minutes Up to 3,000 mpa • S in the peripheral temperature and measurement temperature (if the viscosity of the sample exceeds 500 mpa • s at the peripheral temperature and measurement temperature, bubbles may occur at the time of filling.) Approximately 3.8 kg

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree