Turbine -type pulse output flow meter VT TURBOTRON series-VTH 15k5
Turbine -type pulse output flow meter VT TURBOTRON series-Krone Co., Ltd.

Turbine -type pulse output flow meter VT TURBOTRON series
Krone Co., Ltd.


About This Product

■ Turbine type pulse output ・ The Turabotron Series is a highly reliable product that has been used as standard for the flow rate monitoring of tap water in Germany in Germany. ・ Lightweight, compact, high accuracy, low cost, wide measurement range, can be used for all applications. ■ structure ・ VTH & VTP By the guide blade, the fluid rotates from the four directions to the rotor in the center, and counts it as a pulse when the rotor magnet passes through the hall sensor. 855 Pulses/Liter, NPN Open Collector Output is ± 1 % accuracy and repetition accuracy is ± 0.2 %. ・ VTI If the magnetic body is mixed, you can use SUS as a substitute for magnets, and because it is embedded in each rotor, the parslett can be provided as optional as an option. ・ VTH: Economy print type ・ VTP: High pressure, high temperature specifications ・ VTI: High accuracy, SUS rotor ■ Applications Tap water flow monitoring, etc. * There are other model numbers.

  • Product

    Turbine -type pulse output flow meter VT TURBOTRON series

Share this product


750+ people viewing

Last viewed: 3 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Turbine -type pulse output flow meter VT TURBOTRON series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Conjunction Diameter Electrical connection Material Oling Material pipe Material rotor Material rotor ASSY Material sensor Material shaft/bearing Material unionut nuts Maximum pressure Maximum temperature Measurement range Particle size Protection grade Pulse Reproducibility Resolution Sensor Signal output Supply power supply accuracy filter signal thermometer
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTH 15k5

VTH 15k5

Available upon quote 3/4BSP male union nuts and seals DN15 (inner diameter 15mm) 1.5MPVC cable or 4-pin plug NBR plastic PRI UL TEM (resin) Hard ferrite magnet plastic AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing PA GF 30 1MPa 85 ° C 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 855 pulse/liter ± 0.2% 1.2ml/pulse Hole sensor Detection from 0.3 L/min 4.5VDC-24VDC ± 1% RD Mesh 0.5mm (temperature 60 ° C) Npn PT100, PT1,000 3 lines, 1.5MPVC
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTH 15ms

VTH 15ms

Available upon quote 3/4BSP male union nuts and seals DN15 (inner diameter 15mm) 1.5MPVC cable or 4-pin plug NBR Brass PRI UL TEM (resin) Hard ferrite magnet plastic AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing PA GF 30 1MPa 85 ° C 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 855 pulse/liter ± 0.2% 1.2ml/pulse Hole sensor Detection from 0.3 L/min 4.5VDC-24VDC ± 1% RD Mesh 0.5mm (temperature 60 ° C) Npn PT100, PT1,000 3 lines, 1.5MPVC
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTP 15ms

VTP 15ms

Available upon quote 3/4BSP male, female DN15 (inner diameter 15mm) 1.5m silicon cable Viton Brass PRI UL TEM (resin) Hard ferrite magnet Brass AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing Brass 30MPa 150 ℃ 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 855 pulse/liter ± 0.2% 1.2ml/pulse Hole sensor Detection from 0.3 L/min 4.5VDC-24VDC ± 1% RD - Npn -
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTP 15va

VTP 15va

Available upon quote 3/4BSP male, female DN15 (inner diameter 15mm) 1.5m silicon cable Viton SUS PRI UL TEM (resin) Hard ferrite magnet SUS AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing - 30MPa 150 ℃ 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 855 pulse/liter ± 0.2% 1.2ml/pulse Hole sensor Detection from 0.3 L/min 12VDC-24VDC ± 1% RD - Npn -
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTI 15k5

VTI 15k5

Available upon quote 3/4BSP male union nuts and seals DN15 (inner diameter 15mm) 2MPVC cable or 4-pin plug NBR or VITON plastic PRI UL TEM (resin) SUS pin plastic AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing PA GF 30 1MPa 85 ° C 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 1,795 pulse/liter ± 0.1% 0.6ml/pulse Inductive proximity switch Detection from 0.3 L/min 12VDC-24VDC ± 0.5% RD Mesh 0.5mm (temperature 60 ° C) PNP or NPN PT100, PT1,000 3 lines, 2MPVC
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTI 15ms

VTI 15ms

Available upon quote 3/4BSP male union nuts and seals DN15 (inner diameter 15mm) 2MPVC cable or 4-pin plug NBR or VITON Brass PRI UL TEM (resin) SUS pin plastic AR CAP Shaft AP1D (nickel, copper, etc.) and sapphire bearing PA GF 30 1MPa 85 ° C 2-40 L/min, normal loading 20 L/MLN maximum Up to 0.5mm IP54 1,795 pulse/liter ± 0.1% 0.6ml/pulse Inductive proximity switch Detection from 0.3 L/min 12VDC-24VDC ± 0.5% RD Mesh 0.5mm (temperature 60 ° C) PNP or NPN PT100, PT1,000 3 lines, 2MPVC
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTH 25m S-180

VTH 25m S-180

Available upon quote 1.1/4BSP male DN25 (inner diameter 25mm) 2MPVC cable NBR Brass Pp Hard ferrite magnet plastic SUS and sapphire bearing - 1MPa 85 ° C 4-160 L/Min, normal loading 80 L/MLN maximum Up to 0.5mm P54 67 pulse/liter ± 0.5% 15ml/pulse Hole sensor Detection from 1 L/min 4.5VDC-24VDC ± 3% RD Mesh 0.6mm Npn -
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTH 25k6-180

VTH 25k6-180

Available upon quote 1.1/4BSP male DN25 (inner diameter 25mm) 2MPVC cable NBR plastic Pp Hard ferrite magnet plastic SUS and sapphire bearing - 1MPa 80 ℃ 2Bar
60 ° C 5bar
30 ℃ 10Bar
4-160 L/Min, normal loading 80 L/MLN maximum Up to 0.5mm P54 67 pulse/liter ± 0.5% 15ml/pulse Hole sensor Detection from 1 L/min 4.5VDC-24VDC ± 3% RD Mesh 0.6mm Npn -
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTM 25m S-180

VTM 25m S-180

Available upon quote 1.1/4BSP male DN25 (inner diameter 25mm) 4 -pin plug connector NBR Brass Pp Hard ferrite magnet Brass SUS and sapphire bearing - 5MPA 85 ° C 4-160 L/Min, normal loading 80 L/MLN maximum Up to 0.5mm P54 67 pulse/liter ± 0.5% 15ml/pulse Hole sensor Detection from 1 L/min 4.5VDC-24VDC ± 3% RD Mesh 0.6mm Npn -
Turbine -type pulse output flow meter VT TURBOTRON series-Part Number-VTP 25VA-180

VTP 25VA-180

Available upon quote 1.1/4BSP male DN25 (inner diameter 25mm) 4 -pin plug connector NBR plastic Pp Hard ferrite magnet SUS SUS and sapphire bearing - 5MPA 85 ° C 4-160 L/Min, normal loading 80 L/MLN maximum Up to 0.5mm P54 67 pulse/liter ± 0.5% 15ml/pulse Hole sensor Detection from 1 L/min 4.5VDC-24VDC ± 3% RD Mesh 0.6mm Npn -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree