Product
Measurement area sensor area setting type UXM-30LN-PWHandling Company
Hokuyo ElectricProduct Image | Part Number | Price (excluding tax) | Angle Decomposition Ability | Angle decomposition ability | Case Material Back | Case Material Front Part | Case material back | Case material front part | Current Consumption Current | Current consumption current | Detachment Accuracy | Detachment accuracy | Detected Object | Detected object | Impact Resistance | Impact resistance | Indicator light | Insulation Resistance | Insulation resistance | Light Source | Measurement Principle | Measurement principle | Noise | Output Response Time | Output response time | Power-Supply Voltage | Power-supply voltage | Protective Structure | Protective structure | RANGE | Range | START-UP TIME | Start-up time | Time of Scanning | Time of scanning | USed Peripheral Temperature Humidity | Used peripheral temperature humidity | Vibration Resistance | Vibration resistance | conNection | connection | input | interface | light source | mass | noise |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UXM-30LN-PW |
Available upon quote | STEP ANGLE: 0.25 ° | Step angle: 0.25 ° | Aluminum | Polycarbonate | Aluminum | Polycarbonate | Standing Time: DC10/12V 600ma or Less DC24V 250 MA or Less: DC10V2A or Less DC12V1.5a or Less DC24V0.75A or Below | Standing time: DC10/12V 600mA or less DC24V 250 mA or less: DC10V2A or less DC12V1.5A or less DC24V0.75A or below | Valve Illuminance 3000LX or Less: ± 50mm*1 Peripheral Illuminance 100000LX or Less: ± 100mm*1 | Valve illuminance 3000LX or less: ± 50mm*1 peripheral illuminance 100000LX or less: ± 100mm*1 | 5m: 65mm10m: 130mm30m: 400mm | 5m: 65mm10m: 130mm30m: 400mm | 196m/S2X, Y, Z Each Direction 10 Times Each | 196m/S2X, Y, Z each direction 10 times each | Power Supply Indicator Light: Power Suppry Turns on Lighting/Failure Indicator Light: When Detection → Lighting Failure → Flashing | 10mΩ | 10mΩ | Semiconductor Laser λ = 905nm | TimeOfflight Method | TimeOfflight method | 25db or less | Less Than 100ms | Less than 100ms | DC10-30V | DC10-30V | IP67 | IP67 | 0.1 ~ 30m Maximum Detection Distance: 100m Angle: 190 ° | 0.1 ~ 30m Maximum detection distance: 100m angle: 190 ° | Operation within 30 Seconds of Power Launch | Operation within 30 seconds of power launch | 50ms/scan | 50ms/scan | -10 ~+50 ° C 85%RH or Less. However, Not Condensation / Freezing | -10 ~+50 ° C 85%RH or less. However, not condensation / freezing | Double Shaking Width 1.5mm10-55Hzx, Y, Z Direction 2 Hours Each | Double shaking width 1.5mm10-55Hzx, Y, Z direction 2 hours each | Cable Drawer Type 2m | Cable drawer type 2m | AREA Input 1, 2, 3, 4 | USB2.0 Failure output output 1, 2, 3 Output 1.2.3: Output Off Failure Output by in -Area Detection: Output During Normal Operation on | Semiconductor laser λ = 905nm | APPROXIMATELY 1100g | 25db or less |