Product
Measurement area sensor area setting type URM-40LCHandling Company
Hokuyo ElectricItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Angle Decomposition Ability/Scanning Time | Angle decomposition ability/scanning time | Case Material Optical Window | Case Material Substance | Case material optical window | Case material substance | Distance AVERAGE ACCURACY | Distance average accuracy | Division and Detector | Division and detector | Impact Resistance | Impact resistance | Indicator light | Insulation Resistance | Insulation resistance | Light Source | Measurement and Decomposition Ability | Measurement and decomposition ability | Output Response Time | Output response time | Peripheral term | Power ConsonSamption | Power Current | Power current | Power-Supply Voltage | Power-supply voltage | Protective Structure | Protective structure | Repetition | START-UP TIME | Scanning Angle | Scanning angle | Start-up time | Used peripheral temperature / humidity | Vibration Resistance | Vibration resistance | input | interface | light source | mass | output | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
URM-40LC-EW |
Available upon quote | Ethernet 100BASE-TX | Ethernet 100BASE-TX | Polycarbonate | Aluminum Die-Cast | Polycarbonate | Aluminum die-cast | Detection Warranty Value: 0.1 ~ 40m 0.1 ~ 18m Maximum Detection Distance: 60m Minimum Detection Normal Mode: 65mm 130mm 230mm MM 65mm 130mm | Detection warranty value: 0.1 ~ 40m 0.1 ~ 18m maximum detection distance: 60m minimum detection normal mode: 65mm 130mm 260mm high resolution mode: 33mm 65mm 130mm | 8.4w or less | 8.4W or less | 196m/S2 X, Y, Z Direction 10 Times Each | 196m/S2 X, Y, Z direction 10 times each | -10 ~+50 ℃ 85%RH | 10mΩ | 10mΩ | SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 | 1mm Units | 1mm units | Operates within 15 Seconds of Power On. | Operates within 15 seconds of power on. | 100,000LX | Statate Current Current: DC12V 700ma or Less Starting Current: 1.3A at DC12V | DC10-30V | DC10-30V | SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 | Semiconductor laser λ = 905nm laser safety class 1 | IP67 | IP67 | Reflectant 90%WHITE KENT PAPER 0.1-20m: σ <10mm 20 ~ 40m: σ <15mm | Power Suppry / Operation Indicator Lighting Light Area Judgment Display Light | 270 ° 0.25 ゜/25ms 0.125 ゜/50ms | 270 ° 0.25 ゜/25ms 0.125 ゜/50ms | Power supply / operation indicator lighting light area judgment display light | -10 ~+50 ° C 85%RH (but no freezing or condensation) | 10 to 55Hz Double Width 1.5mm x, Y, Z Direction EACH 2 HOURS 55-200Hz 98m/S2 Sweep 2 MinUTES X, Y, Z Direction 1 Hour Each | 10 to 55Hz double width 1.5mm x, y, Z direction each 2 hours 55-200Hz 98m/S2 sweep 2 minutes x, Y, Z direction 1 hour each | 50ms or less | Output 5 Points: Detection 1/Synchronous Output Detection 2 Detection 3/Synchronous Master Ready Failure | Semiconductor laser λ = 905nm laser safety class 1 | APPROXIMATELY 450g | Input 3 Points: AREA 1 AREA 2 AREA 3/Synchronous Input | Statate current current: DC12V 700mA or less starting current: 1.3A at DC12V | |
URM-40LCN-EW |
Available upon quote | Ethernet 100BASE-TX | Ethernet 100BASE-TX | Polycarbonate | Aluminum Die-Cast | Polycarbonate | Aluminum die-cast | Detection Warranty Value: 0.1 ~ 40m 0.1 ~ 18m Maximum Detection Distance: 60m Minimum Detection Normal Mode: 65mm 130mm 230mm MM 65mm 130mm | Detection warranty value: 0.1 ~ 40m 0.1 ~ 18m maximum detection distance: 60m minimum detection normal mode: 65mm 130mm 260mm high resolution mode: 33mm 65mm 130mm | 8.4w or less | 8.4W or less | 196m/S2 X, Y, Z Direction 10 Times Each | 196m/S2 X, Y, Z direction 10 times each | -10 ~+50 ℃ 85%RH | 10mΩ | 10mΩ | SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 | 1mm Units | 1mm units | Operates within 15 Seconds of Power On. | Operates within 15 seconds of power on. | 100,000LX | Statate Current Current: DC12V 700ma or Less Starting Current: 1.3A at DC12V | DC10-30V | DC10-30V | SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 | Semiconductor laser λ = 905nm laser safety class 1 | IP67 | IP67 | Reflectant 90%WHITE KENT PAPER 0.1-20m: σ <10mm 20 ~ 40m: σ <15mm | Power Suppry / Operation Indicator Lighting Light Area Judgment Display Light | 270 ° 0.25 ゜/25ms 0.125 ゜/50ms | 270 ° 0.25 ゜/25ms 0.125 ゜/50ms | Power supply / operation indicator lighting light area judgment display light | -10 ~+50 ° C 85%RH (but no freezing or condensation) | 10 to 55Hz Double Width 1.5mm x, Y, Z Direction EACH 2 HOURS 55-200Hz 98m/S2 Sweep 2 MinUTES X, Y, Z Direction 1 Hour Each | 10 to 55Hz double width 1.5mm x, y, Z direction each 2 hours 55-200Hz 98m/S2 sweep 2 minutes x, Y, Z direction 1 hour each | 50ms or less | Output 5 Points: Detection 1/Synchronous Output Detection 2 Detection 3/Synchronous Master Ready Failure | Semiconductor laser λ = 905nm laser safety class 1 | APPROXIMATELY 450g | Input 3 Points: AREA 1 AREA 2 AREA 3/Synchronous Input | Statate current current: DC12V 700mA or less starting current: 1.3A at DC12V |
Click on the part number for more information about each product