Measurement area sensor area setting type URM-40LC-URM-40LC-EW
Measurement area sensor area setting type URM-40LC-Hokuyo Electric

Measurement area sensor area setting type URM-40LC
Hokuyo Electric


About This Product

It is an outdoor laser scanner that measures the range of 40m and 270 ° (LIDAR), and can switch between area setting type and data output type. It is possible to separate or filter the rain, fog, etc. by multi -echo correspondence, and also have a dirt detection function of the optical window, making it possible to provide outdoor environmental recognition (SLAM), various out -of -house, and obstacle detection. ROS compatible. URM-40LC-EW (PNP output) / URM-40LCN-EW (NPN output) It is a small, high -performance measuring area sensor of outdoor specifications. ・ In various outdoor environments, we can use it for recognition, invasion of the surrounding environment, and detection of obstacles. ・ A wide range detection of 270 ° angle and 40m distance. 18m is secured for low -reflective objects (black paper). ・ In the case of LA mode (area setting mode), three independent areas can be set freely according to the application. ・ LX data output mode has a multi -epic function, and you can receive multiple echo such as rain and fog for the measurement distance in one direction, and select distance data from each.・ URM-40LC-EW is a 3 echo product. In the case of LA area setting mode, various outdoor filters are mounted, and it is strong against rain and fog. ・ Rain filter ……… It is a filter for moving in the area or detecting randomly. ・ Fog / filter ... Filter for fog and smoke drifting in the air. ・ Sensitivity filter ... A filter that removes weak reflections. It is effective in removing noise such as outer flash and rain. ・ Echo filter… In an environment where multiple echo is incident due to the incident such as raindrops, glass surfaces, and object borders, you can judge with the first echo or the last echo by selecting echo filter.

  • Product

    Measurement area sensor area setting type URM-40LC




*Please note that we may not be able to accommodate sample requests.

2 Models of Measurement area sensor area setting type URM-40LC

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Angle Decomposition Ability/Scanning Time Angle decomposition ability/scanning time Case Material Optical Window Case Material Substance Case material optical window Case material substance Distance AVERAGE ACCURACY Distance average accuracy Division and Detector Division and detector Impact Resistance Impact resistance Indicator light Insulation Resistance Insulation resistance Light Source Measurement and Decomposition Ability Measurement and decomposition ability Output Response Time Output response time Peripheral term Power ConsonSamption Power Current Power current Power-Supply Voltage Power-supply voltage Protective Structure Protective structure Repetition START-UP TIME Scanning Angle Scanning angle Start-up time Used peripheral temperature / humidity Vibration Resistance Vibration resistance input interface light source mass output power consumption
Measurement area sensor area setting type URM-40LC-Part Number-URM-40LC-EW

URM-40LC-EW

Available upon quote Ethernet 100BASE-TX Ethernet 100BASE-TX Polycarbonate Aluminum Die-Cast Polycarbonate Aluminum die-cast Detection Warranty Value: 0.1 ~ 40m 0.1 ~ 18m Maximum Detection Distance: 60m Minimum Detection Normal Mode: 65mm 130mm 230mm MM 65mm 130mm Detection warranty value: 0.1 ~ 40m 0.1 ~ 18m maximum detection distance: 60m minimum detection normal mode: 65mm 130mm 260mm high resolution mode: 33mm 65mm 130mm 8.4w or less 8.4W or less 196m/S2 X, Y, Z Direction 10 Times Each 196m/S2 X, Y, Z direction 10 times each -10 ~+50 ℃ 85%RH 10mΩ 10mΩ SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 1mm Units 1mm units Operates within 15 Seconds of Power On. Operates within 15 seconds of power on. 100,000LX Statate Current Current: DC12V 700ma or Less Starting Current: 1.3A at DC12V DC10-30V DC10-30V SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 Semiconductor laser λ = 905nm laser safety class 1 IP67 IP67 Reflectant 90%WHITE KENT PAPER 0.1-20m: σ <10mm 20 ~ 40m: σ <15mm Power Suppry / Operation Indicator Lighting Light Area Judgment Display Light 270 ° 0.25 ゜/25ms 0.125 ゜/50ms 270 ° 0.25 ゜/25ms 0.125 ゜/50ms Power supply / operation indicator lighting light area judgment display light -10 ~+50 ° C 85%RH (but no freezing or condensation) 10 to 55Hz Double Width 1.5mm x, Y, Z Direction EACH 2 HOURS 55-200Hz 98m/S2 Sweep 2 MinUTES X, Y, Z Direction 1 Hour Each 10 to 55Hz double width 1.5mm x, y, Z direction each 2 hours 55-200Hz 98m/S2 sweep 2 minutes x, Y, Z direction 1 hour each 50ms or less Output 5 Points: Detection 1/Synchronous Output Detection 2 Detection 3/Synchronous Master Ready Failure Semiconductor laser λ = 905nm laser safety class 1 APPROXIMATELY 450g Input 3 Points: AREA 1 AREA 2 AREA 3/Synchronous Input Statate current current: DC12V 700mA or less starting current: 1.3A at DC12V
Measurement area sensor area setting type URM-40LC-Part Number-URM-40LCN-EW

URM-40LCN-EW

Available upon quote Ethernet 100BASE-TX Ethernet 100BASE-TX Polycarbonate Aluminum Die-Cast Polycarbonate Aluminum die-cast Detection Warranty Value: 0.1 ~ 40m 0.1 ~ 18m Maximum Detection Distance: 60m Minimum Detection Normal Mode: 65mm 130mm 230mm MM 65mm 130mm Detection warranty value: 0.1 ~ 40m 0.1 ~ 18m maximum detection distance: 60m minimum detection normal mode: 65mm 130mm 260mm high resolution mode: 33mm 65mm 130mm 8.4w or less 8.4W or less 196m/S2 X, Y, Z Direction 10 Times Each 196m/S2 X, Y, Z direction 10 times each -10 ~+50 ℃ 85%RH 10mΩ 10mΩ SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 1mm Units 1mm units Operates within 15 Seconds of Power On. Operates within 15 seconds of power on. 100,000LX Statate Current Current: DC12V 700ma or Less Starting Current: 1.3A at DC12V DC10-30V DC10-30V SEMICONDUCTOR LASER λ = 905nm Laser Safety Class 1 Semiconductor laser λ = 905nm laser safety class 1 IP67 IP67 Reflectant 90%WHITE KENT PAPER 0.1-20m: σ <10mm 20 ~ 40m: σ <15mm Power Suppry / Operation Indicator Lighting Light Area Judgment Display Light 270 ° 0.25 ゜/25ms 0.125 ゜/50ms 270 ° 0.25 ゜/25ms 0.125 ゜/50ms Power supply / operation indicator lighting light area judgment display light -10 ~+50 ° C 85%RH (but no freezing or condensation) 10 to 55Hz Double Width 1.5mm x, Y, Z Direction EACH 2 HOURS 55-200Hz 98m/S2 Sweep 2 MinUTES X, Y, Z Direction 1 Hour Each 10 to 55Hz double width 1.5mm x, y, Z direction each 2 hours 55-200Hz 98m/S2 sweep 2 minutes x, Y, Z direction 1 hour each 50ms or less Output 5 Points: Detection 1/Synchronous Output Detection 2 Detection 3/Synchronous Master Ready Failure Semiconductor laser λ = 905nm laser safety class 1 APPROXIMATELY 450g Input 3 Points: AREA 1 AREA 2 AREA 3/Synchronous Input Statate current current: DC12V 700mA or less starting current: 1.3A at DC12V

Click on the part number for more information about each product

Other products of Hokuyo Electric


View more products of Hokuyo Electric

About Company Handling This Product

Hokuyo Electric

  • Japan
  • Since 1946
  • 240 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree