Product
Steel / crane sensor CMD PHVHandling Company
Hokuyo ElectricProduct Image | Part Number | Price (excluding tax) | Action mode | Approximately USED HUMIDITY | Approximately used humidity | Detected Object | Detected object | Detection Distance | Detection distance | Fiber Unit Characteristics | Fiber unit characteristics | Insulation Resistance | Insulation resistance | MASS AMPLIFIER UNIT | Mass Fiber UNIT | Mass Sensor Head | Mass amplifier unit | Mass fiber unit | Mass sensor head | Peripheral term | Power ConsonSamption | Power-Supply Voltage | Power-supply voltage | Response Time | Response time | USED Peripheral Temperature | Used peripheral temperature | Vibration Resistance | Vibration resistance | WithStand Voltage | Withstand voltage | action mode | conNection | connection | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PHV |
Available upon quote | Operation When Entering Light/Operation Switching Type WHEN SHADING | 45-85 % RH (But No Freezing) | 45-85 % RH (but no freezing) | Steel Material of φ30 or More (for FHM -20101), φ50 or More (for FHM-211-1) | Steel material of φ30 or more (for FHM-20101), φ50 or more (for FHM-211-1) | 20m | 20m | Available in Tolerant Radius of 100mm, Maximum USED PRESSURE 784MPa, Tensile Strength 490N | Available in tolerant radius of 100mm, maximum used pressure 784MPa, tensile strength 490N | 20mΩ or Higher | 20mΩ or higher | APPROXIMATELY 950G Each | FHV-321 about 1.0kg, FHV-351 about 1.8kg, FHV-411 About 2.8kg | FHM -20101 about 1.2kg, FHM-211-1 about 1.5kg | Approximately 950g each | FHV-321 about 1.0kg, FHV-351 about 1.8kg, FHV-411 about 2.8kg | FHM-20101 about 1.2kg, FHM-211-1 about 1.5kg | Incandescent Light Bulb: 10,000LX | Slower: 4va or less, Light Instrument: 5.5va or Less | AC100-240V (+10 %, -15 %, 50/60Hz) | AC100-240V (+10 %, -15 %, 50/60Hz) | Contact Output: 10ms or Less Without Contact Output: 5ms or Less | Contact output: 10ms or less without contact output: 5ms or less | Amplifier Unit: -10-+45 ° C, Sensor Head Fiber Unit: -10 ~ 200 ° C C | Amplifier Unit: -10-+45 ° C, Sensor Head Fiber Unit: -10 ~+200 ° C | 10 to 55Hz Double Width 1.5mmx, Y, Z Direction 2 Hours Each | 10 to 55Hz double width 1.5mmx, Y, Z direction 2 hours each | AC 1,500V1 Minutes | AC 1,500V1 minutes | Operation when entering light/operation switching type when shading | Connector Type | Connector type | Slower: 4VA or less, light instrument: 5.5va or less |