Product
Cosmopia Large Heat Shock Test Device Large Capacity SeriesHandling Company
Satake Martimics Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Driving noise | Dry air consumption | Dry air pressure | Examination tank dimension depth (mm) | Examination tank dimension height (mm) | Examination tank dimension width (mm) | Exterior | Product dimension depth (mm) | Product dimension height (mm) | Product dimension width (mm) | Protective device | Refrigerant (high temperature side) | Refrigerant (low temperature side) | Telegrated in the test tank | Temperature cycle performance cycle | Temperature cycle performance sample type | Temperature cycle performance sample volume / temperature return time | Temperature cycle performance temperature measurement position | Temperature cycle performance test tank temperature / test time (high temperature) | Temperature cycle performance test tank temperature / test time (low temperature) | Temperature drop time (low temperature tank) | Temperature fluctuation width (℃) | Temperature rising time (high temperature tank) | Test tank capacity (L) | Test temperature range high temperature test (℃) | Test temperature range low temperature test (℃) | accessories | cooling method | method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ES-1006L |
Available upon quote | 65db (a) | Approximately 7.6L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,000 | 750 | 1,450 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 0.5) | 1,805 | 2,200 | 2,355 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | 100kg (samples and shelves 25kg / sheets x 4 or less) | 5 cycle (low temperature start) | Plastic mold IC / iron block |
50kg (iron block equivalent, installed, installed, within 5 minutes) 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes |
Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 75 minutes | ± 0.5 | Room temperature → 130 ° C: within 30 minutes | 1,080 | 60 ~ 120 | -50 ~ -10 | 1 rubber stopper for cable holes, 2 sample shelves, 2 shelves, 4 shelves, operating circuit protection fuse x 2, instruction manual x 1 part, Y strainer x 2 pieces | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-1006LH |
Available upon quote | 65db (a) | Approximately 7.6L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,000 | 750 | 1,450 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 0.5) | 1,805 | 2,200 | 2,355 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | 100kg (samples and shelves 25kg / sheets x 4 or less) | 5 cycle (low temperature start) | Plastic mold IC / iron block |
50kg (iron block equivalent, installed, installed, within 5 minutes) 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes |
Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 75 minutes | ± 0.5 | Room temperature → 130 ° C: within 30 minutes | 1,080 | 60-200 | -65 ~ 0 | 1 rubber stopper for cable holes, 2 sample shelves, 2 shelves, 4 shelves, operating circuit protection fuse x 2, instruction manual x 1 part, Y strainer x 2 pieces | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-1006L-R |
Available upon quote | 65db (a) | Approximately 7.6L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,000 | 750 | 1,450 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 0.5) | 1,805 | 2,200 | 2,355 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | 100kg (samples and shelves 25kg / sheets x 4 or less) | 5 cycle (low temperature start) | Plastic mold IC / iron block |
50kg (iron block equivalent, installed, installed, within 5 minutes) 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes |
Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 75 minutes | ± 0.5 | Room temperature → 130 ° C: within 30 minutes | 1,080 | 60 ~ 120 | -50 ~ -10 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Air -cooled remote condenser type | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-1506L |
Available upon quote | 65db (a) | Approximately 7.6L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,000 | 1,000 | 1,450 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 0.5) | 1,820 | 2,450 | 2,355 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | 100kg (samples and shelves 25kg / sheets x 4 or less) | 5 cycle (low temperature start) | Plastic mold IC / iron block |
50kg (iron block equivalent, installed, installed, within 5 minutes) 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes |
Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 75 minutes | ± 0.5 | Room temperature → 130 ° C: within 30 minutes | 1,450 | 60 ~ 120 | -50 ~ -10 | 1 rubber stopper for cable holes, 2 sample shelves, 2 shelves, 4 shelves, operating circuit protection fuse x 2, instruction manual x 1 part, Y strainer x 2 pieces | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-1506L-R |
Available upon quote | 65db (a) | Approximately 7.6L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,000 | 1,000 | 1,450 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 0.5) | 1,820 | 2,450 | 2,355 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | 100kg (samples and shelves 25kg / sheets x 4 or less) | 5 cycle (low temperature start) | Iron block |
50kg (iron block equivalent, installed, installed, within 5 minutes) 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes |
Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 75 minutes | ± 0.5 | Room temperature → 130 ° C: within 30 minutes | 1,450 | 60 ~ 120 | -50 ~ -10 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Air -cooled remote condenser type | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-2506L |
Available upon quote | 70db (a) | Approximately 20L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,200 | 1,200 | 1,700 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 2.5) | 3,270 | 2,180 | 2,800 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | Up to 150kg (samples and shelves 30kg / step x 5 steps or less) | 5 cycle (low temperature start) | Iron block | 150kg (including iron block equivalent, included in installed gear) / within 10 minutes | Wind side | 85 ° C / 30 minutes | -35 ° C / 30 minutes | Room temperature → -70 ° C: within 90 minutes | ± 0.5 | Room temperature → 150 ° C: within 60 minutes | 2,448 | 60 ~ 130 | -60 ~ 0 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-2906L |
Available upon quote | 70db (a) | Approximately 20L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,200 | 1,200 | 2,000 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 2.5) | 3,270 | 2,180 | 3,100 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | Up to 150kg (samples and shelves 30kg / step x 5 steps or less) | 5 cycle (low temperature start) | Iron block | 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes | Wind side | 120 ° C / 30 minutes | -40 ° C / 30 minutes | Room temperature → -70 ° C: within 90 minutes | ± 0.5 | Room temperature → 150 ° C: within 60 minutes | 2,880 | 60 ~ 130 | -65 ~ 0 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-3106L |
Available upon quote | 70db (a) | Approximately 20L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,450 | 1,200 | 1,800 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 2.5) | 3,520 | 2,300 | 3,365 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | Up to 200kg (sample and shelves 40kg / step x 5 steps or less) | 5 cycle (low temperature start) | Iron block | 200kg (equivalent to iron blocks, included in the mounting of the gear) / within 5 minutes | Wind side | 120 ° C / 30 minutes | -40 ° C / 30 minutes | Room temperature → -70 ° C: within 90 minutes | ± 0.5 | Room temperature → 150 ° C: within 20 minutes | 3,130 | 60 ~ 130 | -65 ~ 0 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched | |
ES-5506L |
Available upon quote | 70db (a) | Approximately 20L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,450 | 1,500 | 2,500 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 2.5) | 3,620 | 2,620 | 4,065 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | Up to 400kg | 5 cycle (low temperature start) | Iron block | 400kg (equivalent to iron blocks, included in installed gear) / within 5 minutes | Wind side | 70 ° C / 30 minutes | -30 ° C / 30 minutes | Room temperature → -70 ° C: within 120 minutes | ± 0.5 | Room temperature → 150 ° C: within 90 minutes | 5,438 | 60 ~ 120 | -50 ~ -10 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched |
Click on the part number for more information about each product