High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-ES-77LH
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-ES-77LH-R
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-ES-107LHH
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Satake Martimics Co., Ltd.

High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series
Satake Martimics Co., Ltd.


About This Product

■ High -performance series adopting inverter control Inverter control has been adopted to improve energy saving. In addition, the use of 100 -cycle continuous operation and the size of the LCD screen are also improved. ■ Reminds the exterior design A stainless steel sheet is adopted for the exterior material, and a clear cover is attached to the left and right of the device. ■ Reduction of power consumption (in energy saving mode) By controlling the high -temperature and low temperature side compressor of the secondary freezing cycle, the power consumption has been reduced compared to conventional machines. ■ 100 cycle continuous operation is adopted as standard In 2 zones (low -temperature tests ⇔ high -temperature test), driving without defrosting is possible for up to 100 cycles. The test time can be reduced by continuous operation. ■ Large LCD screen It has expanded from the conventional 8.4 inch to 10.4 inches (vertical). ■ Language switching function The language displayed in the liquid crystal operation panel can be changed on the operation panel. The corresponding language is four languages: Japanese, English, Chinese (simplified), and Korean. ■ Time second unit setting It is possible to set high temperature, room temperature and low temperature test time in seconds. You can respond to more detailed test conditions. ■ Data log function If an alarm is stopped due to an abnormal detection, it is a function to save the operation status of the device just before the stop in a USB memory. It is useful for failure analysis by collecting data just before the stop. ■ Scroll operation On the screen and trend graphs displaying the scroll bar, you can move from the display area by scrolling and display the hidden part from the screen. ■ Room temperature test time individual settings It is possible to set the room temperature test time after the high temperature test and the normal temperature test time after the low temperature test. It can respond to test conditions stipulated in different test conditions after high temperature and low temperature. ■ Swipe operation Touch the swipe operation area at the top of the screen on the 3 screen of the measurement screen, pattern setting screen, and trend graph screen, and move the screen between the three screens by moving the finger to the right or left.

  • Product

    High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series




*Please note that we may not be able to accommodate sample requests.

10 Models of High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Body configuration member interior Cooling device refrigerant / Output (high temperature side) Cooling device refrigerant / Output (low temperature side) Exam tank content (L) Examination tank dimension depth (mm) Examination tank dimension height (mm) Examination tank dimension width (mm) Exterior of the body composition member Number of continuous operation cycles Product dimension depth (mm) Product dimension height (mm) Product dimension width (mm) Protective device Telegrated in the test tank Temperature cycle performance return time Temperature cycle performance return time warranty number Temperature cycle performance sample mass Temperature cycle performance sample type Temperature cycle performance temperature measurement position Temperature cycle performance test tank temperature / test time (high temperature) Temperature cycle performance test tank temperature / test time (low temperature) Temperature cycle performance test tank temperature / test time (room temperature) Temperature drop time (low temperature tank) Temperature fluctuation width (℃) Temperature rising time (high temperature tank) Temperature setting range pre -cooling temperature Temperature setting range preheating temperature Temperature setting test temperature cooling method method
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-77LH

ES-77LH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 4.5kW (inverter control) R23 / 3.7kW (inverter control) 74 390 460 410 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,400 1,980 1,380 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) Within 5 minutes 5 cycle (low temperature start) 6.5kg (IC4.5kg+jig 2.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 5 minutes Room temperature → -75 ° C: within 50 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-107LH

ES-107LH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 4.5kW (inverter control) R23 / 3.7kW (inverter control) 105 485 460 470 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,400 1,980 1,380 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, 5kg / piece of sample shelves / or less) Within 5 minutes 5 cycle (low temperature start) 7.5kg (IC5.0kg+2.5kg 2.5kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 5 minutes Room temperature → -75 ° C: within 50 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-207LH

ES-207LH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 7.4kW (inverter control) R23 / 4.5kW (inverter control) 200 690 460 630 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,450 1,980 1,535 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) Within 10 minutes 5 cycle (low temperature start) 30kg (IC21kg+2 gear 2 steps 9.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 10 minutes Room temperature → -75 ° C: within 45 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-307LH

ES-307LH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 7.4kW (inverter control) R23 / 4.5kW (inverter control) 305 920 460 720 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,670 1,980 1,625 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) Within 10 minutes 5 cycle (low temperature start) 21kg (IC12kg+2 gear 2 steps 9.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 10 minutes Room temperature → -75 ° C: within 45 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-77LH-R

ES-77LH-R

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 4.5kW (inverter control) R23 / 3.7kW (inverter control) 74 390 460 410 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,400 1,980 1,380 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) Within 5 minutes 5 cycle (low temperature start) 6.5kg (IC4.5kg+jig 2.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 5 minutes Room temperature → -75 ° C: within 50 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Air -cooled remote condenser type Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-107LH-R

ES-107LH-R

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 4.5kW (inverter control) R23 / 3.7kW (inverter control) 105 485 460 470 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,400 1,980 1,380 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, 5kg / piece of sample shelves / or less) Within 5 minutes 5 cycle (low temperature start) 7.5kg (IC5.0kg+2.5kg 2.5kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 5 minutes Room temperature → -75 ° C: within 50 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Air -cooled remote condenser type Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-207LH-R

ES-207LH-R

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 7.4kW (inverter control) R23 / 4.5kW (inverter control) 200 690 460 630 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,450 1,980 1,535 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) Within 10 minutes 5 cycle (low temperature start) 30kg (IC21kg+2 gear 2 steps 9.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 10 minutes Room temperature → -75 ° C: within 45 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Air -cooled remote condenser type Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-307LH-R

ES-307LH-R

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 7.4kW (inverter control) R23 / 4.5kW (inverter control) 305 920 460 720 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,670 1,980 1,625 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) Within 10 minutes 5 cycle (low temperature start) 21kg (IC12kg+2 gear 2 steps 9.0kg) Plastic mold IC Wind side 150 ° C / 30 minutes -65 ° C / 30 minutes Atmosphere temperature / 10 minutes Room temperature → -75 ° C: within 45 minutes ± 0.5 Room temperature → 200 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Air -cooled remote condenser type Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-107LHH

ES-107LHH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 4.5kW (inverter control) R23 / 3.7kW (inverter control) 105 485 460 470 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,400 1,980 1,380 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) Within 3 minutes 5 cycle (low temperature start) 5kg (IC2.5kg+jigs per step 2.5kg) Plastic mold IC Wind side 125 ° C / 30 minutes -55 ℃ / 30 minutes - Room temperature → -75 ° C: within 50 minutes ± 0.5 Room temperature → 150 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance Series-Part Number-ES-207LHH

ES-207LHH

Available upon quote Stainless steel plate (SUS304, 2B polishing finish) R404A / 7.4kW (inverter control) R23 / 4.5kW (inverter control) 200 690 460 630 Stainless steel plate (SUS430, hairline finish) 100 cycle (low temperature start) 1,450 1,980 1,535 Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) Within 3 minutes 5 cycle (low temperature start) 10kg (IC5.5kg+jigs per step 4.5kg) Plastic mold IC Wind side 125 ° C / 30 minutes -55 ℃ / 30 minutes - Room temperature → -75 ° C: within 45 minutes ± 0.5 Room temperature → 150 ° C: within 20 minutes -80 ° C ~ Test tank temperature low temperature setting value Temple temperature high temperature setting value ~ 210 ° C Low-temperature test: -70 ~ 0 ℃
High temperature test: 60-200 ° C
Two -yield frozen (water -cooled) with a mechanical compressor Still, cold / warm air switching method, 2 zones / 3 zones can be switched

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Satake Martimics Co., Ltd.


View more products of Satake Martimics Co., Ltd.

About Company Handling This Product

Satake Martimics Co., Ltd.

  • Japan
  • Since 1920
  • 200 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree