Product
High -performance series that uses inverter control Cosmopia Gourant Heat Shock Test Machine High Performance SeriesHandling Company
Satake Martimics Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Body configuration member interior | Cooling device refrigerant / Output (high temperature side) | Cooling device refrigerant / Output (low temperature side) | Exam tank content (L) | Examination tank dimension depth (mm) | Examination tank dimension height (mm) | Examination tank dimension width (mm) | Exterior of the body composition member | Number of continuous operation cycles | Product dimension depth (mm) | Product dimension height (mm) | Product dimension width (mm) | Protective device | Telegrated in the test tank | Temperature cycle performance return time | Temperature cycle performance return time warranty number | Temperature cycle performance sample mass | Temperature cycle performance sample type | Temperature cycle performance temperature measurement position | Temperature cycle performance test tank temperature / test time (high temperature) | Temperature cycle performance test tank temperature / test time (low temperature) | Temperature cycle performance test tank temperature / test time (room temperature) | Temperature drop time (low temperature tank) | Temperature fluctuation width (℃) | Temperature rising time (high temperature tank) | Temperature setting range pre -cooling temperature | Temperature setting range preheating temperature | Temperature setting test temperature | cooling method | method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ES-77LH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 4.5kW (inverter control) | R23 / 3.7kW (inverter control) | 74 | 390 | 460 | 410 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,400 | 1,980 | 1,380 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) | Within 5 minutes | 5 cycle (low temperature start) | 6.5kg (IC4.5kg+jig 2.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 5 minutes | Room temperature → -75 ° C: within 50 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-107LH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 4.5kW (inverter control) | R23 / 3.7kW (inverter control) | 105 | 485 | 460 | 470 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,400 | 1,980 | 1,380 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, 5kg / piece of sample shelves / or less) | Within 5 minutes | 5 cycle (low temperature start) | 7.5kg (IC5.0kg+2.5kg 2.5kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 5 minutes | Room temperature → -75 ° C: within 50 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-207LH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 7.4kW (inverter control) | R23 / 4.5kW (inverter control) | 200 | 690 | 460 | 630 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,450 | 1,980 | 1,535 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) | Within 10 minutes | 5 cycle (low temperature start) | 30kg (IC21kg+2 gear 2 steps 9.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 10 minutes | Room temperature → -75 ° C: within 45 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-307LH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 7.4kW (inverter control) | R23 / 4.5kW (inverter control) | 305 | 920 | 460 | 720 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,670 | 1,980 | 1,625 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) | Within 10 minutes | 5 cycle (low temperature start) | 21kg (IC12kg+2 gear 2 steps 9.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 10 minutes | Room temperature → -75 ° C: within 45 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-77LH-R |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 4.5kW (inverter control) | R23 / 3.7kW (inverter control) | 74 | 390 | 460 | 410 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,400 | 1,980 | 1,380 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) | Within 5 minutes | 5 cycle (low temperature start) | 6.5kg (IC4.5kg+jig 2.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 5 minutes | Room temperature → -75 ° C: within 50 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Air -cooled remote condenser type | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-107LH-R |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 4.5kW (inverter control) | R23 / 3.7kW (inverter control) | 105 | 485 | 460 | 470 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,400 | 1,980 | 1,380 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, 5kg / piece of sample shelves / or less) | Within 5 minutes | 5 cycle (low temperature start) | 7.5kg (IC5.0kg+2.5kg 2.5kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 5 minutes | Room temperature → -75 ° C: within 50 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Air -cooled remote condenser type | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-207LH-R |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 7.4kW (inverter control) | R23 / 4.5kW (inverter control) | 200 | 690 | 460 | 630 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,450 | 1,980 | 1,535 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) | Within 10 minutes | 5 cycle (low temperature start) | 30kg (IC21kg+2 gear 2 steps 9.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 10 minutes | Room temperature → -75 ° C: within 45 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Air -cooled remote condenser type | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-307LH-R |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 7.4kW (inverter control) | R23 / 4.5kW (inverter control) | 305 | 920 | 460 | 720 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,670 | 1,980 | 1,625 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) | Within 10 minutes | 5 cycle (low temperature start) | 21kg (IC12kg+2 gear 2 steps 9.0kg) | Plastic mold IC | Wind side | 150 ° C / 30 minutes | -65 ° C / 30 minutes | Atmosphere temperature / 10 minutes | Room temperature → -75 ° C: within 45 minutes | ± 0.5 | Room temperature → 200 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Air -cooled remote condenser type | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-107LHH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 4.5kW (inverter control) | R23 / 3.7kW (inverter control) | 105 | 485 | 460 | 470 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,400 | 1,980 | 1,380 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 30kg (bottom 20kg or less, sample shelf 5kg / or less) | Within 3 minutes | 5 cycle (low temperature start) | 5kg (IC2.5kg+jigs per step 2.5kg) | Plastic mold IC | Wind side | 125 ° C / 30 minutes | -55 ℃ / 30 minutes | - | Room temperature → -75 ° C: within 50 minutes | ± 0.5 | Room temperature → 150 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched | |
ES-207LHH |
Available upon quote | Stainless steel plate (SUS304, 2B polishing finish) | R404A / 7.4kW (inverter control) | R23 / 4.5kW (inverter control) | 200 | 690 | 460 | 630 | Stainless steel plate (SUS430, hairline finish) | 100 cycle (low temperature start) | 1,450 | 1,980 | 1,535 | Electrical leakage breakers, electricity overload protection devices, high -pressure blocking devices, temperature fuse, door open operation prevention switch, temperature rise prevention device, protective fuse | Up to 50kg (bottom 40kg or less, sample shelf 12kg / or less) | Within 3 minutes | 5 cycle (low temperature start) | 10kg (IC5.5kg+jigs per step 4.5kg) | Plastic mold IC | Wind side | 125 ° C / 30 minutes | -55 ℃ / 30 minutes | - | Room temperature → -75 ° C: within 45 minutes | ± 0.5 | Room temperature → 150 ° C: within 20 minutes | -80 ° C ~ Test tank temperature low temperature setting value | Temple temperature high temperature setting value ~ 210 ° C |
Low-temperature test: -70 ~ 0 ℃ High temperature test: 60-200 ° C |
Two -yield frozen (water -cooled) with a mechanical compressor | Still, cold / warm air switching method, 2 zones / 3 zones can be switched |
Click on the part number for more information about each product