Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Driving noise
Dry air consumption
Dry air pressure
Examination tank dimension depth (mm)
Examination tank dimension height (mm)
Examination tank dimension width (mm)
Exterior
Product dimension depth (mm)
Product dimension height (mm)
Product dimension width (mm)
Protective device
Refrigerant (high temperature side)
Refrigerant (low temperature side)
Telegrated in the test tank
Temperature cycle performance cycle
Temperature cycle performance sample type
Temperature cycle performance sample volume / temperature return time
Temperature cycle performance temperature measurement position
Temperature cycle performance test tank temperature / test time (high temperature)
Temperature cycle performance test tank temperature / test time (low temperature)
Temperature drop time (low temperature tank)
Temperature fluctuation width (℃)
Temperature rising time (high temperature tank)
Test tank capacity (L)
Test temperature range high temperature test (℃)
Test temperature range low temperature test (℃)
accessories
cooling method
method
Part Number
ES-2906LHandling Company
Satake Martimics Co., Ltd.Items marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Driving noise | Dry air consumption | Dry air pressure | Examination tank dimension depth (mm) | Examination tank dimension height (mm) | Examination tank dimension width (mm) | Exterior | Product dimension depth (mm) | Product dimension height (mm) | Product dimension width (mm) | Protective device | Refrigerant (high temperature side) | Refrigerant (low temperature side) | Telegrated in the test tank | Temperature cycle performance cycle | Temperature cycle performance sample type | Temperature cycle performance sample volume / temperature return time | Temperature cycle performance temperature measurement position | Temperature cycle performance test tank temperature / test time (high temperature) | Temperature cycle performance test tank temperature / test time (low temperature) | Temperature drop time (low temperature tank) | Temperature fluctuation width (℃) | Temperature rising time (high temperature tank) | Test tank capacity (L) | Test temperature range high temperature test (℃) | Test temperature range low temperature test (℃) | accessories | cooling method | method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 70db (a) | Approximately 20L (ANR) per cycle | 0.4 ~ 0.7MPa | 1,200 | 1,200 | 2,000 | Cold pressurized steel plate, natural gray (Mansel symbol 1.0Y8.5 / 2.5) | 3,270 | 2,180 | 3,100 | Electrical leakage breakers, electric fuse protection devices, electric fuses, temperature hood prevention devices, door open operation prevention switches, temperature fuse, high -pressure blocking devices for freezer | R404A | R23 | Up to 150kg (samples and shelves 30kg / step x 5 steps or less) | 5 cycle (low temperature start) | Iron block | 100kg (iron block equivalent, installed, mounting soldier amount) / within 10 minutes | Wind side | 120 ° C / 30 minutes | -40 ° C / 30 minutes | Room temperature → -70 ° C: within 90 minutes | ± 0.5 | Room temperature → 150 ° C: within 60 minutes | 2,880 | 60 ~ 130 | -65 ~ 0 | Cable hole rubber stopper x 1, 2 sample shelves, 4 shelves x 4, operation circuit protection fuse x 2 pieces, instruction manual x 1 part | Water -cooled | Still, cold and cold cooling method, 2 zones / 3 zones can be switched |