Direct drive motor large torque cylinder type τid roll fan air -cooled ID seriesHandling Company
CKD Nisshin Electrical Corporation Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Approximately used humidity | Detected pulse | Encoder type | Insulated pressure | Insulating class | Maximum torque (forced air cooling) N.M | Model | Mounting direction | Power supply ACV | Protection grade | Rated output kw | Rated rotation number RPM | Rated torque (forced air cooling) N.M | Rotor Motor Motor Motor KG, ㎡ | Used peripheral temperature (℃) | Vibration resistance | cooling method | elevation | mass |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID300-490-151A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 450 | NMR-DSDZA4A- □ AAAZ: (382g, 792N) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 3.8 ~ 7.9 | 240 ~ 500 | 150 | 0.057 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 62 | |
ID300-590-301A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 800 | NMR-DSDZA4A- □ AAAZ: (752g, 163n) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 7.5 ~ 15.7 | 240 ~ 500 | 300 | 0.12 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 91 | |
ID380-650-381A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 1,000 to 1,100 | NMR-DTFZA4A- □ AAAZ: (482E, 962g, 143J, 193m, 243p, 293R) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 4.8 ~ 28.7 | 120 ~ 720 | 380 | 0.26 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 256 | |
ID380-650-501A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 1,450 ~ 1,600 | NMR-DTFZA4A- □ AAAZ: (632E, 133G, 193J, 253m, 313p, 383R) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 6.3 ~ 37.7 | 120 ~ 720 | 500 | 0.3 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 271 | |
ID380-850-871A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 1,900 to 2,300 | NMR-DTHZA4A- □ AAAZ: (113E, 223G, 333J, 413m, 473P, 523R) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 10.9 ~ 52 | 120 ~ 720 | 690 ~ 870 | 0.48 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 374 | |
ID380-850-112A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 2,400 to 3,100 | NMR-DTHZA4A- □ AAAZ: (143E, 283G, 423J, 483m, 523P, 623R) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 13.8 ~ 61.8 | 120 ~ 720 | 820 ~ 1,100 | 0.56 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 405 | |
ID450-870-162A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 4,000 | NMR-DUHZA4A- □ AAAZ: (103c, 153D, 203E, 303F, 403G, 503H) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 10.1 ~ 50.3 | 60-300 | 1,600 | 1.58 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 608 | |
ID450-870-192A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 4,800 to 5,000 | NMR-DUHZA4A- □ AAAZ: (123c, 183D, 243E, 353F, 483G, 603H) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 11.9 ~ 59.7 | 60-300 | 1,850 to 1,900 | 1.87 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 648 | |
ID450-970-282A |
Available upon quote | 85%or less without condensation | 2097152 | Absolute (1 revolution) | AC1,500V, 1 minute | F's F | 4,000 to 7,000 | NMR-DUJZA4A- □ AAAZ: (183c, 263D, 353E, 533F, 703G, 793H) | Rotation axis horizontal or vertical | 3 phase 400 | Equivalent to IP44 (excluding rotation axes and terminal boxes) | 17.6 ~ 78.5 | 60-300 | 2,500 to 2,800 | 2.43 | 0 ~ 40 | 1g (3 directions 2 times) | Forced air -cooled (power supply used cooling blower: 3 phase AC200V) | 1,000m or less | 751 |
Click on the part number for more information about each product